18
7.7 Hopper Cleaning
Saw residues may block the auger. There-
fore, pellet hopper must be emptied and
cleaned each 10/20 refills, depends on the
quantity of dust in the pellets. Faulty hop-
per cleaning can void the warranty, with the
manufacturer declining all related liability.
7.8 Annual service
Annually contact the local Technical Support
for service and check up of the following
components:
• Door gaskets;
• Ash box gaskets;
• Exchanger gaskets;
• Tube bundle silicone gaskets;
• Ash Reducer gaskets;
• Tube bundle cleaning;
• Pellet hopper cleaning;
• Capative sensor cleaning (if available);
• Air flux sensor cleaning (if available);
• Boiler interspace cleaning;
• Internal flue pipe cleaning;
• Air pipeline cleaning;
• Exhaust fan base cleaning;
• Motherboard cleaning;
• Floor protection cleaning;
• Hot air tangential fan cleaning;
• Ignition resistance;
• Burning pot’s integrity;
• Gearmotor integrity;
• Expansion vessel;
• Bushings.
At the end of the maintenance the techni-
tian must fill the maintenance document,
which is required to maintain the guaran-
tee.
Lack of annual maintenance voids
the factory boiler/thermostove war-
ranty. The annual maintenance is re-
sponsibility of the customer.
7.9 Maintenance Summary
Components
Each
ignition
Each 3
days
Each 15
days
Each 30
days
If full or
dirty
Each
year
Burner
•
*
Exchanger
•
*
•
*
Ash Box
•
*
•
*
Inspection Com-
partment
•
•
Glass
•
Ceramic Fiber Gaskets
•
**
Gaskets
•
**
Internal Flue Duct
•
**
Pump
•
**
Plate Heat Exchanger
•
**
Main Components
•
**
Boiler/stove body
•
**
Chimney
•
***
Pellet tank and Additio-
nal Box
•
•
**
* automatic where available ** contact local Customer Support *** contact qualified personnel