QUICK MANUAL (RO30G, RO30C, RO60S)
•
The RO unit should not be shut down
for more than 7 days.
•
If the system is shut down for longer,
it has to be maintained.
•
Nevertheless, the device should not
be exposed to frost,
because the membrane is protected
only externally.
1. Bridge the resin cartridge.
2. Unscrew the filter cup in the pre-filter
group and remove the filter element.
3. Insert the feed pipe in the black filter.
Transverse hole must be at the bottom.
4. Fill the maintenance fluid into the right
filter cup and firmly attach it again.
5. Connect the system to the water supply.
Both water outputs must remain open.
Make sure the system is switched off!
6. Open the water inlet valve and allow the
inflowing water to flow freely through the
system (No power!)
7. Make sure that the water inlet valve
does not remain open for more than 10
seconds. There is a risk that the entire
maintenance fluid will be completely
flushed out.
To protect the membrane, proceed as follows:
1. Disconnect the water supply if
connected.
2. Connect the concentrate hose so that
excess water can drain.
3. Disconnect the exit hose from the
pre-filter case.
4. Put the hose into the bottle of the
maintenance fluid.
5. Place the bottle securely.
6. Start the pump.
7. The bottle is now quickly sucked
empty.
8. As soon as the bottle is empty,
stop the system
9. Re-connect the hose to the
pre-filter case.
Re-commissioning:
1. Disconnect the concentrate and
the hose from the bottom of the
DI filter.
2. Lead the hoses into a bucket.
3. Connect the tab water line.
•
Start the Pump at the control box.
•
Press the
buttons until you read
FIL in the display.
•
The pump flushes the membrane.
4. Now the water is flushed into the bucket.
Let it run for at least 30 minutes to
asure that no maintenance fluid is in
the system. Reconnect the hose to the
system like in picture 1.
HiFlo RO30G, RO30C, RO60S
HydroPower RO XXL (Trailer)
RO-PURE WATER FILTER SYSTEM
Membrane Protection