Contents under pressure can cause severe injury
or death from tank rupture.
When starting system:
•Checksystemforcracks.
•Besurecoverisinlockedposition.
•Donotexceedpressureof115psi(8Bar).
•Keepdischargelineopenandholdyellowlever
downtoremovetrappedairfromsystem.
•Foruseonlywithdrinkingwater
Beforeservicingsystem:
•Shutoffdrinkingwatersupplyandopen
waterfedwashpoletubingdischargeline.
•Disconnectwatersupplyandallowtanktodrain.
DANGER
!
Spilledresinisaslippinghazard.
Cleanupspilledresinimmediately.
WARNING
!
Resin can cause skin irritation.
Avoid skin contact.
Washhandsthoroughlyafteruse.
Can cause eye irritation.
Avoid eye contact.
Wearsafetygoggles.
Incaseofeyecontact,immediatelyflush
eyesthoroughlywithcleanwater.
Consultdoctorifsymptomspersist.
CAUTION
!
STORAGE:
Donotstoreresin
inopenorunlabeledcontainers.
Storeinacool(15°Fto100°F),
dryplace.
DISPOSAL:
Disposeofin
accordancewithapplicable
federal,state/provincial,and
localregulations.
AllHydroPowermodels
requiretheuseofmixed
bedionexchangeresin
(commonlyreferredtoas
de-ionizingresin).
Thisresinwillrequire
replacementandhandling.
System Overview
The nLite HydroPower
TM
–
The Future of DI Systems... Today
• Inspect system – ensure DI resin bag(s) are installed.
• Set up system in upright position.
• Choose a stable onsite location.
• Quick connect fittings are supplied with the HydroPower system.
• Thread garden hose directly onto inlet connection on/off valve.
• Install quick connect adapter to waterfed wash pole hose.
• Ensure all waterfed wash pole on/off valves are in “OPEN” position.
• Inspect system as it pressurizes and begins producing “purewater”
• Turn on TDS meter and inspect “purewater” quality. A reading of ‘0’
contains zero parts per million total dissolved solids).
• Adjust flow at waterfed wash pole brush head by:
- On/Off Valve
- Waterfed wash pole control (on/off) valve.
• Disconnect waterfed wash pole tubing.
• Depress yellow lever on system head assembly.
• Use a counter-clockwise quarter-turn to release
• Reach into housing and remove exhausted resin
• Drop in new resin bag(s) by hand – be sure to seat bags
with zip-tie facing up. Pat down bag by hand to
• Inspect system head assembly: O-ring and
distribution filter are in good condition.
Re-coat O-ring with silicone lubricant only.
• Re-install DI System head assembly, push down firmly,
then quarter-turn clockwise.
• System is ready to be operated.
• Turn “ON’ water supply.
FastLock
TM
Lever
Quick Connect Adapter
FloWater
TM
Distribution Filter
System Inlet
Connection for
On/Off Valve
TDS Meter
Output Valve
Housing with
Rugged Outside
Appearance
QuickChange
TM
Resin Bag
(Packed inside unit)