ungerglobal.com
•Checksystemforcracks.
•Besurecoverisinlockedposition.
•Donotexceedpressureof115psi(8Bar).
•Keepdischargelineopenandholdyellowlever
downtoremovetrappedairfromsystem.
•Foruseonlywithdrinkingwater
Beforeservicingsystem:
•Shutoffdrinkingwatersupplyandopen
waterfedwashpoletubingdischargeline.
•Disconnectwatersupplyandallowtanktodrain.
Spilledresinisaslippinghazard.
Cleanupspilledresinimmediately.
Washhandsthoroughlyafteruse.
Wearsafetygoggles.
Incaseofeyecontact,immediatelyflush
eyesthoroughlywithcleanwater.
Consultdoctorifsymptomspersist.
Donotstoreresin
inopenorunlabeledcontainers.
Storeinacool(15°Fto100°F),
dryplace.
Disposeofin
accordancewithapplicable
federal,state/provincial,and
localregulations.
AllHydroPowermodels
requiretheuseofmixed
bedionexchangeresin
(commonlyreferredtoas
de-ionizingresin).
Thisresinwillrequire
replacementandhandling.
System Set Up
LOCATE JOBSITE WATER SUPPLY
Unger recommends testing the onsite water supply for both tem-
perature and TDS (total dissolved solids) prior to working. Higher TDS
levels reduce the DI systems capacity.
• Inspect system – ensure DI resin bag(s) are installed.
• Set up system in upright position.
• Choose a stable onsite location.
CONNECT WATER SUPPLY (GARDEN HOSE)
TO SYSTEM INLET CONNECTION
• Quick connect fittings are supplied with the HydroPower system.
• Thread garden hose directly onto inlet connection on/off valve.
CONNECT WATERFED WASH POLE TUBING
• Install quick connect adapter to waterfed wash pole hose.
• Ensure all waterfed wash pole on/off valves are in “OPEN” position.
TURN FEED WATER SUPPLY “ON” SLOWLY
• Inspect system as it pressurizes and begins producing “purewater”
• Turn on TDS meter and inspect “purewater” quality. A reading of ‘0’
is best and indicates the system is running properly (product water
contains zero parts per million total dissolved solids).
• Adjust flow at waterfed wash pole brush head by:
- On/Off Valve
- Waterfed wash pole control (on/off) valve.
1
2
3
4
1
Building/Facility
2
3
4
Replacing DI Resin
SHUT-OFF FEED WATER SUPPLY
• Disconnect waterfed wash pole tubing.
• Depress yellow lever on system head assembly.
RELEASE SYSTEM HEAD ASSEMBLY
• Use a counter-clockwise quarter-turn to release
system head assembly; remove and set aside.
• Reach into housing and remove exhausted resin
by hand; discard according to local regulations.
REPLACE RESIN
• Drop in new resin bag(s) by hand – be sure to seat bags
with zip-tie facing up. Pat down bag by hand to
ensure seated properly.
• Inspect system head assembly: O-ring and
FloWater
TM
distribution filter are in good condition.
Re-coat O-ring with silicone lubricant only.
• Re-install DI System head assembly, push down firmly,
then quarter-turn clockwise.
• System is ready to be operated.
RECONNECT WATERFED WASH POLE TUBING
• Turn “ON’ water supply.
TEST SYSTEM TDS
1
2
3
4
5
1
2
3
4
5