background image

For more information, visit our website at: www.unibondlighting.com

[

Grouping Mode

]

Synchronization Manual

E-905A LED Warning Lights

Simultaneous Sync:

 

Lamp units will only flash together if in the same group

Single Flash = Group 1

Double Flash = Group 2

Alternating Sync:

 

Lamp units in Group 1 will flash alternately with lamp units in group 2

This is a built-in mode that lets you set your groups for syncing

Steps below must be done before installing/mounting the lamp for use

Determine the Sync Group you want for your set-up

In 

[

Grouping Mode

]

, the lamp will be blinking dimly. Briefly tap Pattern Selection

(Yellow wire) to the power source and 

SET EACH LAMP TO THE SAME GROUP

- refer to 

[

Grouping Mode

]

 above

Connect the Black wire to Ground. Connect Red wire & Yellow wire at the same time 

to a power

source to enter 

[

Grouping Mode

]

.

Disconnect the power source to exit 

[Grouping Mode

].

In 

[

Grouping Mode

]

, the lamp will be blinking dimly. Briefly tap Pattern Selection

(Yellow wire) to the power source and 

SET LAMPS TO EITHER GROUP 1 or GROUP 2

- refer to 

[

Grouping Mode

]

 above

Re-connect only the Red wire to the power source. Briefly tap Pattern Selection

(Yellow wire) to the power source to change patterns

- refer to (

1.1 Flash Patterns

) of Installation Manual

These lights can be synchronized to flash simultaneously or alternately. To flash alternately,

you must determine which group each light will be in. You need not have the same number

of lights in each group. To sync simultaneous, all lights must be in the same group.

Once all lamps are set to the same patterns, connect all Yellow wires together.

Disconnect the power source to exit 

[Grouping Mode

].

Re-connect only the Red wire to the power source. Briefly tap Pattern Selection

(Yellow wire) to the power source to change patterns

- refer to (

1.1 Flash Patterns

) of Installation Manual

Once all lamps are set to the same patterns, connect all Yellow wires together.

For Wiring & Flash Patterns - (

refer to Installation Manual

)

Summary of Contents for E-905A

Page 1: ...res Light should be fused with 5 Amp Fuse ATM05 sold separately For 12V to 24V DC Applications Tap yellow wire Pattern Selection to Power momentarily to change patterns see Flash Patterns To return to pattern NO 1 touch the yellow wire to Power quickly 3 times NOTE This unit may not be factory set to Flash Pattern NO 1 NO Flash Patterns SAE 1 2 3 4 5 6 7 8 Double Flash 2Hz Single Flash 2Hz Triple ...

Page 2: ...ntre Lampes être fusionné avec à un fusible de 5 ampères ATM05 vendu séparément Pour applications 12V à 36V DC Toucher le fil jaune Choix de configuration au puissance pour changer de configuration voir le Configurations de clignotants Pour revenir à la configuration NO 1 toucher le fil jaune au Puissance rapidement 3 fois NOTE Ce module peut ne pas être réglé à la configuration NO 1 par le manufa...

Page 3: ...nd should be replaced immediately Inspect and operate this product regularly to confirm its proper operation and mounting condition Do not use a pressure washer to clean this product It is recommended that these instructions be stored in a safe place and referred to when performing maintenance and or reinstallation of this product FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTRUCTIONS COULD R...

Page 4: ...es pourrait résulter à la décoloration ou au craquement prématuré de la lentille Dans ces conditions l efficacité en serait sérieusement réduite et devrait être remplacée immédiatement Inspecter et mettre en marche ce produit régulièrement afin de s assurer que le montage et le fonctionnement sont en bonne condition Ne pas utiliser de laveuse à pression pour le nettoyage Il est recommandé de garde...

Page 5: ... In Grouping Mode the lamp will be blinking dimly Briefly tap Pattern Selection Yellow wire to the power source and SET LAMPS TO EITHER GROUP 1 or GROUP 2 refer to Grouping Mode above Re connect only the Red wire to the power source Briefly tap Pattern Selection Yellow wire to the power source to change patterns refer to 1 1 Flash Patterns of Installation Manual These lights can be synchronized to fl...

Page 6: ...ière dans chaque groupe Pour synchroniser simultanément toutes les lumières doivent être du même groupe Débrancher le bloc d alimentation Mode de Groupe Rebrancher seulement le fil rouge au bloc d alimentation Toucher brièvement le choix de configuration fil jaune au bloc d alimentation pour changement de configuration référer à 1 1 Configurations de Clignotants Lorsque toutes les lumières sont sur la ...