For more information, visit our website at: www.unibondlighting.com
[
Grouping Mode
]
Synchronization Manual
E-916 Series LED Warning Lights
Simultaneous Sync:
Lamp units will only flash together if in the same group
Single Flash = Group 1
Double Flash = Group 2
Alternating Sync:
Lamp units in Group 1 will flash alternately with lamp units in group 2
This is a built-in mode that lets you set your groups for syncing
Steps below must be done before installing/mounting the lamp for use
Determine the Sync Group you want for your set-up
In
[
Grouping Mode
]
, the lamp will be blinking dimly. Briefly tap Pattern Selection
(Brown wire) to the power source and
SET EACH LAMP TO THE SAME GROUP
- refer to
[
Grouping Mode
]
above
Connect the Black wire to Ground. Connect White wire & Brown wire at the same time to a power
source to enter
[
Grouping Mode
]
.
Disconnect the power source to exit [Grouping Mode].
In
[
Grouping Mode
]
, the lamp will be blinking dimly. Briefly tap Pattern Selection
(Brown wire) to the power source and
SET LAMPS TO EITHER GROUP 1 or GROUP 2
- refer to
[
Grouping Mode
]
above
Re-connect only the White wire to the power source. Briefly tap Pattern Selection
(Brown wire) to the power source to change patterns
- refer to (
1.1 Flash Patterns
) of Installation Manual
These lights can be synchronized to flash simultaneously or alternately. To flash alternately,
you must determine which group each light will be in. You need not have the same number
of lights in each group. To sync simultaneous, all lights must be in the same group.
Once all lamps are set to the same patterns, connect all Brown wires together.
Disconnect the power source to exit [Grouping Mode].
Re-connect only the White wire to the power source. Briefly tap Pattern Selection
(Brown wire) to the power source to change patterns
- refer to (
1.1 Flash Patterns
) of Installation Manual
Once all lamps are set to the same patterns, connect all Brown wires together.
•
•
•
•
•
•
•
•
For Wiring & Flash Patterns - (
refer to Installation Manual
)