background image

3

Specifications

Capacity @ 80°F/60%RH:

  140 Pints Per Day

Capacity @ 73°F/60%RH:

   100 PPD

Airflow @ 0.0” SP: 

 400CFM

Operating Temp. Range:

  35.6-105°F

Operating Relative Humidity Range:

  36%-90%

COP:

  2.75 L/kWh

Refrigerant: 

 R410A

Amperage Usage:

  8.3 Amps

Power Supply: 

 115V/60Hz/Single Phase

Outlet Requirement: 

 15 Amp

Sound Level: 

 60 dBa

Dimensions LxWxH:

  23.6” x 22” x 37.2” (600 x 560 x 947 mm)

ETL Listed: 

 Yes

How It Works

Installation

1. Place dehumidifier on a level surface.

2. Set up the drain line

3. Plug dehumidifier into grounded 15 amp circuit. 

Uni-P Dry dehumidifiers use an integrated humidistat to monitor theconditioned space. When 

the relative humidity goes above the selected setpoint, the dehumidifier will energize. Air is 

then drawn across an evaporator coil, which is cooler than the dew point of air. This means 

moisture will condense out of the air. The air is then reheated through the condenser coil and 

distributed back into the room.

• Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a 
level surface. 

• If unit has been turned or flipped so that the compressor did not remain upright, place the 
unit on a level surface and wait a minimum of 2 hours before proceeding.

• Locate the dehumidifier near a suitable drain (6' drain hoseincluded). Allow for proper 
drainage and routing of needed drain pipes. 

• Connect the drain pipe to the quick connector of the dehumidifier before placing the drain 
pipe into the sewer. 

• The dehumidifier is equipped with a built-in drainage pump to support the drainage height 
of 18 '. 

4

1. Power Key

• 

Use this button to turn the dehumidifier on and off.

• 

Press once to turn machine on. You will hear two beeps and the        light will 

illuminate green (solid or flashing depending on mode).

• Press the power button a second time and you will hear one beep as the machine shuts 
down. Note that there is a 1 minute fan delay.   

2. Arrow Buttons

·

Use the up and down arrow buttons to set the desired humidity setpoint on the display 

screen.                              

·

The setpoint can be any number between 36%-90%. When the  indoor humidity is higher 

than the setpoint, the unit will operate.
 • Keep in mind that the displayed humidity levels are approximate   ( +/-5%)

3. Continuous Mode

• 

To set the unit to run continuously regardless of humidity,   simply use the down 

arrow key to set the humidity below 36%.

Key Functions

• 

The continuous light will illuminate green and the display will show   “CO”.

• To switch back to normal humidistat operation, use the arrow keys to

move the setpoint above 36%. 

4. Manual Drain Button   

• If you need to store or move your dehumidifier, press the “Drain” button to remove water 
from the integral pump’s reservoir.    

5. Pump Trouble Warning

• If the pump reservoir level gets too high, the water sensor will activate to prevent 
overflow. 

•When this occurs, the compressor will stop automatically, and the display will show “E4”. 
After a 1 minute delay, the fan motor will turn off and the dehumidifier will not operate until 
the problem has been resolved. 

•Check to verify that the pump is functioning, then unplug the unit for two minutes to reset 

the error code. 

Tel: 888-994-0895

Tel: 888-994-0895

Uni-P Renegade1400X 

AIR MOVERS

Installation, Operation & Service Instructions

Uni-P Renegade1400X 

AIR MOVERS

Installation, Operation & Service Instructions

Summary of Contents for Renegade 1400X

Page 1: ...Uni P Renegade 1400X Dehumdifiers Installation Operation Service Instructions Add 2048 E Francis St Ontario CA 91761 Tel 888 994 0895 E mail sales unipdry com READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...e dehumidifier has been flooded unplug the unit remove the cover and allow it to dry completely before proceeding Do not insert objects or your fingers into the inlet or discharge Do not use water to...

Page 3: ...height of 18 4 1 Power Key Use this button to turn the dehumidifier on and off Press once to turn machine on You will hear two beeps and the light will illuminate green solid or flashing depending on...

Page 4: ...The remote connects to your dehumidifier via a 25 CAT 5 cable with the integrated sensor giving you multiple options for monitoring surrounding conditions Example 1 Install the dehumidifier in the lau...

Page 5: ...e 140X has an integrated condensate pump During normal operation the 140X will automatically drain as required If you would like to store or move your unit press the drain button to drain water from t...

Page 6: ...ur the cleaning solution into the drain tray at the base of the coils If any cleaning solution gets on the coils flush with water 5 Allow solution to soak for 15 minutes 6 Reconnect the dehumidifier t...

Page 7: ...ne isn t sufficient Solution Cause Symptom Poor Connection Verify that both ends of the power cord are plugged in Power Outage Reset power Trouble Code LO Clean the filter Clear the blockage Filter is...

Page 8: ...pacitor Coil Assembly Hot Gas Valve Assembly Condensate Pump Assembly Filters External Components N 200 N 201 Prefilter MERV 10 N 202 HEPA N 203 Carbon Filter N 125 Foot adjustable Cables N 102 N 121...

Page 9: ...LL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE Uni P Dry s total liability regardless of nature of claim...

Reviews: