background image

9

Cleaning the Filter  

                

1. Unplug the unit.
2. For PreFilter:
    a. Remove prefilter from inlet of machine.
    b. Vacuum or wash with warm water (no soap). 
3. For MERV-10/HEPA/Carbon Filters:
    a. Replace as necessary- we recommend 
        checking the filters at least 1x/year

Electrical Access 

                

• Unscrew the 9 screws on the side panel.

• Remove the 1 screws on the 

  control board cover. 

Pump Maintenance

                

Your 140X is equipped with an integral condensate pump
designed to pump water from the dehumidifier out to the desired drain. 

The pump requires routine maintenance that is not covered by the warranty. 

Preventative maintenance is necessary to prevent issues from dirt and slime that may 
accumulate in the drain system. This includes the drain pan, hose to the condensate pump, 
pump reservoir, pump head assembly, and discharge tubing. 

Coil Maintenance

• Once per year, clean the coils with an approved coil cleaner. The

coil cleaner should be a self-rinsing, foaming, cleaner, such as 
WEB® Coil Cleaner.

**

For more detailed instructions, visit www.unipdry.com

**

       WARNING: Always unplug the unit before doing any maintenance.

Cleaning the Machine Body 

• Use a soft, damp cloth to clean the exterior of unit. Do not use any 

soap or solvents 

Maintenance

Basic Pump Cleaning

          

Complete about once per year, depending on environment 

1. Remove filter(s) from inlet of unit to access drain tray. Press the drain button to drain the 
reservoir.

2. Disconnect power to the dehumidifier.

3. Mix a 16 ounce solution of bleach (1 oz 15 oz water) OR vinegar (4 oz white 
v 12 oz water).

4. Pour the cleaning solution into the drain tray at the base of the coils. 
If any cleaning solution gets on the coils, flush with water. 

5. Allow solution to soak for 15 minutes.

6. Reconnect the dehumidifier to power.

7. Fill the reservoir with water (16-32 ounces) and flush/cycle the pump at least 2x.

8. If the drain line is still filled with debris, repeat process. If drain line still does not appear 
clean, move on to Advanced Cleaning.

1. Press the drain button to drain the water from the reservoir (a wet-dry vacuum or towels 
can be used to remove any remaining water).

2. Unplug the dehumidifier and remove the cover so you have access to the pump.

3. Remove the pump head from the reservoir by unscrewing the screw.
Wipe reservoir clean with a paper towel.

4. Reassemble pump.

5. Mix a 16 ounce solution of bleach (1 oz 15 oz water) OR vinegar (4 oz white 
v 12 oz water).

6. Pour the cleaning solution into the drain tray at the base of the coils.
If any cleaning solution gets on the coils, flush with water.

7. Allow solution to soak for 15 minutes.

8. Reconnect the dehumidifier to power.

9. Fill the reservoir with water (16-32 ounces) and flush/cycle the pump at least 2x.

Removing the Pump

                

1. Remove the 7 screws on the side panel and set 
panel aside.
2. Remove the screw holding the pump in place.
3. Undo the 3 pump electrical quick connects and 1 
drain quick connect.
4. Insert a flat head screwdriver into the notch on the 
side of the pump. This will allow you to 
gently lift the pump off its reservoir (the reservoir 
remains attached to the unit). 

10

Tel: 888-994-0895

Tel: 888-994-0895

Uni-P Renegade1400X 

AIR MOVERS

Installation, Operation & Service Instructions

Uni-P Renegade1400X 

AIR MOVERS

Installation, Operation & Service Instructions

Summary of Contents for Renegade 1400X

Page 1: ...Uni P Renegade 1400X Dehumdifiers Installation Operation Service Instructions Add 2048 E Francis St Ontario CA 91761 Tel 888 994 0895 E mail sales unipdry com READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...e dehumidifier has been flooded unplug the unit remove the cover and allow it to dry completely before proceeding Do not insert objects or your fingers into the inlet or discharge Do not use water to...

Page 3: ...height of 18 4 1 Power Key Use this button to turn the dehumidifier on and off Press once to turn machine on You will hear two beeps and the light will illuminate green solid or flashing depending on...

Page 4: ...The remote connects to your dehumidifier via a 25 CAT 5 cable with the integrated sensor giving you multiple options for monitoring surrounding conditions Example 1 Install the dehumidifier in the lau...

Page 5: ...e 140X has an integrated condensate pump During normal operation the 140X will automatically drain as required If you would like to store or move your unit press the drain button to drain water from t...

Page 6: ...ur the cleaning solution into the drain tray at the base of the coils If any cleaning solution gets on the coils flush with water 5 Allow solution to soak for 15 minutes 6 Reconnect the dehumidifier t...

Page 7: ...ne isn t sufficient Solution Cause Symptom Poor Connection Verify that both ends of the power cord are plugged in Power Outage Reset power Trouble Code LO Clean the filter Clear the blockage Filter is...

Page 8: ...pacitor Coil Assembly Hot Gas Valve Assembly Condensate Pump Assembly Filters External Components N 200 N 201 Prefilter MERV 10 N 202 HEPA N 203 Carbon Filter N 125 Foot adjustable Cables N 102 N 121...

Page 9: ...LL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE Uni P Dry s total liability regardless of nature of claim...

Reviews: