background image

14

N-100

N-101

N-102

N-801

N-118

N-800

N-119

N-803

Spare Parts

Remote Control

W-100

W-101

Remote Control Assembly
(includes W-101 and 
W-102)

Remote Control

W-102

Remote Control
Cable

Fan Components

N-802

N-804

Fan Motor

Complete Fan 
Assembly

N-117

Fan Capacitor

Display/Control

Main Control 
Board

Display Board

RH/Temp.
Sensor

Internal Components

Compressor

Compressor Capacitor

Coil Assembly

Hot Gas Valve Assembly

Condensate Pump Assembly

F External Components

N-200

N-201

 Prefilter

MERV 10

N-202

HEPA

N-203

Carbon Filter

N-125

Foot, adjustable

Cables

N-102

N-121

Temp/RH Sensor Cable

Display Ribbon Cable

N-122

CAT 5 Port Internal Cable

Duct + Ventilation Accesspries

N-103

N-105


Supply Duct Collar
Assembly

Remote Control

13

Limited Warranty

Tel: 888-994-0895

Tel: 888-994-0895

Uni-P Renegade1400X 

AIR MOVERS

Installation, Operation & Service Instructions

Uni-P Renegade1400X 

AIR MOVERS

Installation, Operation & Service Instructions

Summary of Contents for Renegade 1400X

Page 1: ...Uni P Renegade 1400X Dehumdifiers Installation Operation Service Instructions Add 2048 E Francis St Ontario CA 91761 Tel 888 994 0895 E mail sales unipdry com READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...e dehumidifier has been flooded unplug the unit remove the cover and allow it to dry completely before proceeding Do not insert objects or your fingers into the inlet or discharge Do not use water to...

Page 3: ...height of 18 4 1 Power Key Use this button to turn the dehumidifier on and off Press once to turn machine on You will hear two beeps and the light will illuminate green solid or flashing depending on...

Page 4: ...The remote connects to your dehumidifier via a 25 CAT 5 cable with the integrated sensor giving you multiple options for monitoring surrounding conditions Example 1 Install the dehumidifier in the lau...

Page 5: ...e 140X has an integrated condensate pump During normal operation the 140X will automatically drain as required If you would like to store or move your unit press the drain button to drain water from t...

Page 6: ...ur the cleaning solution into the drain tray at the base of the coils If any cleaning solution gets on the coils flush with water 5 Allow solution to soak for 15 minutes 6 Reconnect the dehumidifier t...

Page 7: ...ne isn t sufficient Solution Cause Symptom Poor Connection Verify that both ends of the power cord are plugged in Power Outage Reset power Trouble Code LO Clean the filter Clear the blockage Filter is...

Page 8: ...pacitor Coil Assembly Hot Gas Valve Assembly Condensate Pump Assembly Filters External Components N 200 N 201 Prefilter MERV 10 N 202 HEPA N 203 Carbon Filter N 125 Foot adjustable Cables N 102 N 121...

Page 9: ...LL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE Uni P Dry s total liability regardless of nature of claim...

Reviews: