TROUBLESHOOTING PROCEDURES PROCEDURE 1
Blocked Fluid Passage In Diaphagm Pump
If the pump sounds like it is working but liquid does not flow,
clear the fluid passage as follows:
•
Remove suction tube from the pail and blow air at 85 PSI
into the INLET Liquid Hose (see diagram). Step on foot
pedal to activate pump. This procedure may have to be
repeated several times. If this procedure does not help,
blow some water into the suction hose using a spray gun,
wait one minute and step on foot pedal to activate pump.
This procedure may have to be repeated several times. If
this procedure does not work, the pump must be replaced.
If you need to replace the pump call the Uni-ram Service
Engineer.
The warranty on the diaphragm pump is two
years from date of purchase.
This procedure will also clear a blockage in the fluid line for the brush. Follow the same procedure to
clear a blockage in the automatic nozzle except turn the timer instead of stepping on the foot pedal.
PROCEDURE 2
Blocked Air Passage In Diaphragm Pump
If there is a steady hissing sound and the pump is not
cycling, the spool valve has stalled due to a blocked air pas-
sage. Follow the procedure below to clear the blockage.
•
Connect a blow gun to an 85 PSI source. Locate the
blue hose that extends from the air exhaust port of
the diaphragm pump. Use a blow gun to blow air into
the open end of this hose. Turn timer. If the procedure
is successful, the pump will start working. The proce-
dure may have to be repeated several times. If this
procedure does not work, replace the pump.
•
Cause:
Contaminants in the air supply (water, oil,
solid particles etc)
•
Preventative Action:
If necessary, install an Airline (Moisture) Filter.
PROCEDURE 3
Blocked Passage in Air Line
The components in the air line are the
diaphragm pump, air valve, foot pedal, 3-way ball valve
and regulator. See the Flow Diagram and the section: Replacement Parts.
To troubleshoot a component:
1) Disconnect the air line to the component using the quick disconnect.
2) Step on foot pedal and check for presence of positive air pressure in the air line. If there is ample
positive air pressure, replace the component.
If air pressure is absent, there is a faulty component upstream. Reconnect the air line and check the
operation of the next component upstream by following steps 1 and 2 above.
Summary of Contents for UG2000DMV
Page 8: ...8 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 ...
Page 11: ...11 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 TROUBLE SHOOTING ...
Page 12: ...12 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 ...
Page 17: ...17 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 ...
Page 19: ...19 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 ...