background image

  PLACE THE SPRAY GUN IN THE CLEANING TANK:

 •   Place the spray gun on a nozzle extension in the wash tank with 
     the air cap facing the corner. Select the nozzle extension that best fits your spray
     gun. There is a fixed nozzle extension in the wash tank and push-on extensions in the 
     accessory kit. 

 

  PREPARE THE SPRAY GUN FOR CLEANING:

 •  Loosen the air cap 2 turns. 
 •  Use the Trigger Lock Spring (120-350) as shown 
    in the photos to the right to hold the trigger in the 
     open position.

 

  WASH CYCLE: 

  •   Close the lid of the cleaning tank and turn the 
     “Auto Wash Timer” clockwise to start cleaning. 
      The wash cycle takes about 60 seconds.  
  •   Push and hold the “Air Rinse” button for about 2 
     seconds to evacuate the wash solvent.   
  •  Press and hold the “Clean Rinse” button  for about 
   2 seconds to send 100 cc of clean solvent through the 
    jets to rinse the spray guns. Clean-rinse is limited to 
     100 cc of solvent to minimize consumption. 
     Wait 30 seconds before re-using the clean rinse to allow the rinse pump to refill.
  •  Push and hold the “Air Rinse ” button for about 2 second to air-rinse the guns.  
  •  After cleaning the spray guns, remove the guns from the tank and wipe them dry. 
     Do not store spray guns and cups in the wash tank.
  •  Clean any splashed paint from the spray gun cleaner.

  

PRE-CLEAN: 

 •  Disconnect the spray gun from the air line and remove the 
 cup.
 •  Squirt solvent into the paint channel allowing waste solvent 
    to drain into a waste container (not supplied). (photo on right)
     If you have a conventional cup drain paint into waste container. 

UG5000W 

- SOLVENT TANK 

STANDARD OPERATING PROCEDURES 
 

 

 

 
  To prevent solvent from entering the air passage way of your spray gun:
 •   Insert the white plastic plug into the air fitting of the spray gun. If you have 
     removed the air fitting, attach the knurled nut (attached to the Trigger Lock Spring)
     to the air passageway of the spray gun.
     

  USING THE FLOW-THROUGH BRUSH:

 •   Step on the foot pedal to send wash solvent 
     through the Brush to wash the spray gun. See photo on 
     right. 
 •   Solvent flow is set at the factory but may be adjusted 
     using the left side “Brush Flow Control”. See photo on far 
     right. 
 •  To increase flow, loosen the locking nut, rotate the 
   dial anti-clock wise, and tighten the locking nut. 

Trigger Lock Spring

Trigger Lock 
Spring in 
position

Air Plug

(140-230)

Nozzle 
Extrension

Auto Wash 
Timer  

Air Rinse

Clean 
Rinse

Flow-Through Brush 

Brush Flow 
Control

  

 For detailed instructions refer to your user manual or the user manual at www.uniram.com, Technical Support.

SOP-UG5   JULY 2020

PUSH

PUSH

Reviews: