5
MANUAL - SPRAY GUN CLEANERS - UG7500 SERIES
REVISION 2011-05
SETUP
INSPECTION
•
Inspect the shipping carton for signs of damage. It is your responsibility to report damage to the
transport company. Uni-ram Corporation does not accept responsibility for shipping damage
once the machine has left our warehouse. Keep the packaging materials until you are sure the
machine has not been damaged during shipping.
•
Remove the machine from the carton by opening the bottom flaps and sliding the carton up over
the machine.
•
Make sure the bag of accessories contains the following:
• Manual
•
Kit - Plug, Guns W.Trigger Lock Springs, 2 pieces (Part No. 140-2340)
•
Nozzle Adapters, 1 each of 2 kinds (Part No. 110-430 and 110-430PPS)
•
Hood Door Support (Part No. 780-3723)
•
Remove the protective covers on all the oulets.
If any items are missing, contact your supplier.
LOCATION
Position in a well-ventilated area away from sparks, heat and open flames.
LEVELING, VENT AND AIR SUPPLY
•
Level the machine using the adjustable legs.
•
Attach a vent hose (not supplied) to the vent outlet on top of the
machine. The duct system must not be under continuous vacuum.
•
Attach an air supply adapter (not supplied) to Air Inlet Fitting (see
right).
The air supply pressure must be at least 85 PSI and
the air must be free from contaminants such as water, dust, rust, tar,
grease etc.
To prevent damage to the Diaphragm Pump an internal Air Pressure
Regulator has been installed to limit the air pressure to precisely 85
PSI. Do not install a second air pressure regulator or use a pressure
set below 85 PSI.