5
MANUAL - UG7500W SERIES SPRAY GUN CLEANERS
REVISED 2020-10
• Check to ensure the Drain Valve is in the open
position (handle in vertical position) and drain hose
is in the (left) pail.
PAIL SETUP
•
Open the cabinet door.
•
The spray gun cleaner comes with two plastic pails. The black drain hose, suction hose and brush
hose are inserted into the plastic wash pail. See the photo of the unit below. The Rinse pump and
suction pipe for the rinse spigot is installed in the clean pail. The stainless steel inlet filter is located
at the end of the suction hose and prevents debris from reaching the pump and wash tank. See
the photo of the filter below. Clean the filter monthly. The procedure to clean the filter is described
in the Section, MONTHLY MAINTENANCE.
• Pour the contents of
AQUA-KLEEN
into the tank. Pour 3 gal (12 L) of water into the wash tank to fi ll
the wash pail.
AQUA-KLEEN
enhances the cleaning power of water. Move the suction hose to the
clean pail after removing the cap and pour the contets of the second bottle of AQUA-KLEEN into the
tank. Pour 5 gallons (19 L) of water in the the cleaning tank. Return the drain hose to the wash pail.
Note 1: Stainless steel inlet fi lter located on end
of suction hose
Drain Valve
Open
Closed
cabinet
Drain Hose
Wash Pail
See Note 1 below
Spigot Brush
Suction Hose for Wash
tank
Hose for Rinse Pump
and spigot
Wash Pail
Stainless Steel Filter
Suction hoses for
Spigot and Brush
Drain Valve
Drain Valve
Drain Valve