Programming Manual MSO/UPO2000 Series
110 / 156
Instruments.uni-trend.com
:SBUS
:FR:END
:TYPE?
Query returns STATIC.
:SBUS:FR:ERRor:TYPE
Command format
:
:SBUS
:FR
:ERRor:TYPE
{HEADCRC| ENDCRC | NULLSTATIC|NULLDYNAMIC|SYNC|START}
:SBUS
:FR
:ERRor:TYPE?
Functional description
:
This command is used to set FlexRay bus trigger condition error type of the oscilloscope.
{HEADCRC|ENDCRC|NULLSTATIC|NULLDYNAMIC|SYNC|START}: header CRC, end frame, null static, bull
dynamic, synchronization frame, start frame.
Return format
:
Query returns {HEADCRC| ENDCRC | NULLSTATIC|NULLDYNAMIC|SYNC|START}.
For example
:
:SBUS
:FR
:ERRor:TYPE SYNC
Set FlexRay bus trigger condition error type to synchronization.
:SBUS
:FR
:ERRor:TYPE?
Query returns SYNC.
AWG Command
This command is used to set the built-in signal source.
Channel Command
This command is used to set the built-in signal source.
AWG:CHANnel<n>:OUTPut
Command format
:
AWG:CHANnel<n>:OUTPut {{1 | ON} | {0 | OFF}}
AWG:CHANnel<n>:OUTPut?
Functional description
:
This command is used to turn on/off the specified channel output.
<n>: channel number, n take value from 1, 2.
Return format
:
Query returns the output status of the specified channel. 0 represents OFF, 1 represents ON.
For example
:
AWG:CHANnel1:OUTPut ON
Turn on channel 1 output.
AWG:CHANnel1:OUTPut?
Query returns 1.