Programming Manual MSO/UPO2000 Series
96 / 156
Instruments.uni-trend.com
Return format
:
Query returns binary character data.
For example
:
:SBUS:CAN:DATA "X00X00X1"
Set CAN bus data to X00X00X1.
:SBUS:CAN:DATA?
Query returns X00X00X1.
CAN-FD
This command is used to set the relevant parameter of CAN-FD bus decoding and trigger.
:SBUS:CANFD:SOURce
Command format
:
:SBUS:
CANFD
:SOURce {CHANnel1|CHANnel2|CHANnel3|CHANnel4|<Dx>}
:SBUS:
CANFD
:SOURce?
Functional description
:
This command is used to set CAN-FD bus input source of the oscilloscope.
<Dx>: It presents the oscilloscope has LA function and it can set D0-D15 channel as the bus decoding source.
Return format
:
Query returns {CHANnel1|CHANnel2|CHANnel3|CHANnel4|<Dx>}.
For example
:
:SBUS:
CANFD
:SOURce CHANnel1
Set channel 1 as CAN-FD bus input source.
:SBUS:
CANFD
:SOURce?
Query returns CHANnel1.
:SBUS:CANFD:SIGNal:DEFinition
Command format
:
:SBUS:
CANFD
:SIGNal:DEFinition { CANH | CANL}
:SBUS:
CANFD
:SIGNal:DEFinition?
Functional description
:
This command is used to set CAN-FD bus signal tyoe of the oscilloscope.
Return format
:
Query returns { CANH | CANL}.
For example
:
:SBUS:
CANFD
:SIGNal:DEFinition CANH
Set channel 1 CAN-FD bus signal type to CANH.
:SBUS:
CANFD
:SIGNal:DEFinition?
Query returns CANH.
:SBUS:CANFD:BAUDrate
Command format
: