background image

Quick Start Guide                                                                                                                                                                        MSO/UPO2000 Series

 

 

14 / 18

 

 

Instruments.uni-trend.com 

7.3    Drag 

Use one finger to press and drag the selected item to the aimed position as shown in Figure 9. Drag gesture 
can use for:   

 

Drag waveform to change waveform displacement or offset.   

 

Drag window control to change window position (such as numeric keyboard).   

 

Drag cursor to change cursor position. 
 

 

            Figure 9 Drag Gesture 

 

7.4    Drawing Rectangle 

Open function guide and tap drawing rectangle icon to switch drawing rectangle mode. Drag finger on the 
screen to drawing rectangle as shown in Figure 10(a), 10(b). Move finger away from the screen, menu displayed 
on the screen, tap to select “Area A enable”, “Area B enable”, “Intersection”, “Non-intersecting”, “Source”. Drag 
finger on the screen form bottom right up to top left to drawing the trigger area. 
 

 

     

 

(a)                                                                            (b)   

Figure 10 Drawing Rectangle Gesture 

Select “Area A”:   

 

Drawing the area of trigger area A; 

 

Open trigger area A; 

 

Open “trigger area” menu.   

Select “Area B”:   

 

Drawing the area of trigger area B;   

 

Open trigger area B;   

Summary of Contents for MSO2000 Series

Page 1: ...Quick Start Guide MSO UPO2000 Series Digital Phosphor Oscilloscope...

Page 2: ...V1 00 Statement UNI T products are protected by patent rights in China and foreign countries including issued and pending patents UNI T reserves the rights to any product specification and pricing cha...

Page 3: ...n the Warning statement are not properly executed or observed Do not proceed to the next step until you fully understand and meet the conditions stated in the Warning statement Caution Caution indicat...

Page 4: ...from CAT III circuit or sockets more than 20 meters away from CAT IV circuit CAT III Primary circuit of large equipment directly connected to the distribution board and circuit between the distributi...

Page 5: ...s product before it is powered on AC power supply Please use the AC power supply specified for this device Please use the power cord approved by your country and confirm that the insulation layer is n...

Page 6: ...f UNI T for testing Any maintenance adjustment or parts replacement must be done by the relevant personnel of UNI T Cooling Do not block the ventilation holes at the side and back of this device Do no...

Page 7: ...Series digital phosphor oscilloscope includes four models Model Analog Channel Analog bandwidth LA AWG UPO2102 2 100MHz UPO2104 4 100MHz UPO2202 2 200MHz UPO2204 4 200MHz MSO2102 2 100MHz MSO2104 4 1...

Page 8: ...lease keep the packaging and notify both the transportation department and UNI T distributors UNI T will arrange maintenance or replacement 3 2 Before Use To perform a quick verification of the instru...

Page 9: ...and connect the probe to CH1 Make sure the probe s connector is properly connected with the oscilloscope Connect the probe s main clip and ground clip to the oscilloscope s compensating signal and gro...

Page 10: ...g waveform 14 Horizontal control HORIZONTAL 4 Jog dial knob 15 Analog channel input port 5 Function menu 16 Vertical control VERTICAL 6 Numeric keypad 17 Menu control soft key 7 Automatic control key...

Page 11: ...trend com 5 Rear Panel Figure 4 Rear Panel Table 2 Rear Panel No Description No Description 1 EXT Trig port 5 LAN 2 AUX Out and arbitrary waveform signal output 6 AC Power Input Socket 3 VIDEO Out 7 P...

Page 12: ...status identification 9 System time 2 Time base scale 10 USB DEVICE icon 3 Sampling rate storage depth 11 CH4 state icon 4 Waveform indicator 12 CH3 state icon 5 Waveform trigger position 13 CH2 stat...

Page 13: ...on the screen and then to setup Tap the function guide icon on the left corner of the screen to enable it Tap to pop out numeric keypad to set parameter Tap virtual keyboard to set label and file nam...

Page 14: ...ng Rectangle Open function guide and tap drawing rectangle icon to switch drawing rectangle mode Drag finger on the screentodrawing rectangle asshowninFigure 10 a 10 b Move fingeraway fromthescreen me...

Page 15: ...5 Touch Shortcut Operating Separate two fingers and meanwhile slide two fingers to one direction this gesture can quickly turn on off time measurement and voltage measurement cursor a Time measuremen...

Page 16: ...This symbolrepresentsthat numeric keypad on the front panel or touchto pop out numeric keyboard to input content This symbol represents that the current page can be flipped up or down Circle numbers...

Page 17: ...red voltage amplitude value is 10 times larger or smaller than the actual value Check the channel probe attenuation coefficient setting is consistent with the used probe attenuation rate 4 There is a...

Page 18: ...5 30pm UTC 8 Monday to Friday or via email Our email address is infosh uni trend com cn For product support outside mainland China please contact your local UNI T distributor or sales center Many UNI...

Reviews: