74
/
99
b. IP Address
:
IP address format is nnn.nnn.nnn.nnn
,
the first nnn range is from 1 to 233, the
second nnn range is from 0 to 255. It is recommended that user can consult network
administrator for an available subnet mask.
c.
Submask Setting
:
the format is nnn.nnn.nnn.nnn
,
the nnn range is from 1 to 255. It is
recommended that user can consult network administrator for an available subnet mask.
(9) Time Setting
Time Setting can set the time, year, month, date, hour, minute independently by adjusting the knob
to switch the setting. After the setting, the oscilloscope will display the setting time.
(10) Boot Loading
Boot Loading can set whether to automatically set the settings before the shutdown when the
oscilloscope starts up. It can set the last setting or the default setting.
Last setting: Load all the settings before shutdown;
Default setting: restore the oscilloscope to the default factory setting after starting up.
13.2 Recording Waveform
Recording Waveform can set to record the waveform, this function includes recording setting, record,
stop and display.
(1) Recording Setting
Set the parameter of recording waveform, which includes recording interval, end of frame, playback
delay and the maximum frame
a. Recording Interval
:
Set the interval between each frame of the waveform recording.
b. End of Frame
:
The waveform recording will automatically stop recording when it reaches the
end frame.
c.
Playback Delay
:
Set the interval time between each frame during the waveform playback.
d. Maximum Frame
:
Displays the maximum number of frames that can be recorded in the current
situation, it cannot be modified (The maximum number of frames will be changed by memory
depth).
(2) Record
Star to recording.
(3) Stop
Stop the recording.
(4) Playback
Playback the waveform, press the knob can stop playback. Adjusting the Multipurpose knob to skip
to the specified frame.