Measurement Operation(4)
C.Resistance Testing
(see figure 5)
(figure 5)
Warning
To avoid damages to the Meter or to the devices
under test, disconnect circuit power and discharge
all the high-voltage capacitors before measuring
resistance.
Never attempt an in-circuit current measurement
where the open circuit voltage between terminals
and ground is greater than 60V DC or 30V AC rms.
The resistance ranges are: 200.0
Ω
, 2.000k
Ω
, 20.00k
Ω
,
200.0k
Ω
, 2.000M
Ω
and 20.00M
Ω
.
To measure resistance, connect the Meter as follows:
1. Insert the red test lead into the
Ω
terminal and the
black test lead into the
COM
terminal.
2. Set the rotary switch to an appropriate measurement
position in
Ω
range.
3. Connect the test leads across with the object being
measured.
The measured value shows on the display.
Model UT105: OPERATING MANUAL