Accuracy: (a% r b digits), guarantee for 1 year.
Operating temperature: 23
o
C 5
o
C
Relative humidity: 75%R.H
Temperature coefficient: 0.1x(specified accuracy)/1
o
C
2.000V
20.00V
200.0V
600V
1mV
10mV
100mV
1V
Range
Resolution
(1.2%+5)
Overload
Protection
Accuracy
(1.5%+5)
600V rms
A. AC Voltage: Auto ranging
Remarks:
l
Input impedance: 10M
Ω
//<100pF”
l
Displays effective value of sine wave (mean value
response).
l
Frequency response: 40Hz~1kHz.
l
To adjust reading in accordance with effective value
B. DC Voltage: Auto ranging
200.0mV
2.000V
20.00V
200.0V
600V
Range
Resolution
(0.8%+1)
Overload
Protection
Accuracy
(1%+3)
600V rms
0.1mV
1mV
10mV
100mV
1V
(0.8%+3)
Remarks:
Input impedance: 10M
Ω .
Accurate Specifications(1)
Model UT201/202: OPERATING MANUAL
27