background image

P/N:110401104488X

Figure 1

5.3 Operating Instruction

5.3.1 Determine Phase Sequence (Contact Type) 

5.3.2 Check Rotary Field (Motor Rotation, Non-Contact Type)

Note: This non-contact test is applicable for both 

          single-phase and three-phase motors. The 

          instrument will be unable to indicate accurately 

          with motors controlled by frequency converter, 

          its LED indicators can not work normally.

Figure 2

Figure 3

R LED indicator is on when the motor 

otates clockwise.

5.4 Detect Magnetic Field

Place UT261B into solenoid valve, press “ON” button. If “Clockwise” (R) or “Counter-clockwise” (L) rotation 

indicator illuminates, indicating magnetic field exists in the area.

 Do not use corrosive or solution since those substances will cause damage to the chassis 

    of UT261B. 

 Prior to cleaning, remove all testing leads from UT261B. 

VI. Maintenance 

     

Note

To prevent damage to UT261B:  

 Repairing or Maintaining  UT261B can only be performed by qualified technicians. 

 Make sure you know clearly precise calibration procedures and function tests, and read enough 

 maintenance information

Replacement and disposal of battery

         Note, Warning 

  To prevent electric shocking, it is necessary to remove all testing leads from UT261B prior to replacing

 replace the battery.  

    

 UT261B contains 9V/6F22 battery, do not discard the battery with other solid wastes and  the used 

 battery should be handed over to the qualified waste collector or dangerous substance transporter for

  proper treatment and disposal.   

   

    

 Please replace the battery as follows and see the  Figure 3:  

1. Remove all testing leads from UT261B. 

2. Take off the protective casing.

3. Place UT261B with face down on the non-abrasive surface, and 

    screw out screws on 

    the battery cover with proper screw driver. 

4. Take off battery cover from UT261B and take out battery after 

    loosening the battery  buckle.  

   

5. Replace battery as per the method shown in the  figure, 

    and watch out for the battery polarity. 

     

6. Reinstall the battery cover with screws. 

The manual information is subject to changes without prior notice!

**END**

a. Insert test leads (L1,L2,L3) into the corresponding input terminals of UT261B(U,V,W) respectively and 

    then connect them to alligator clips.

b. Then connect alligator clips in L1, L2 and L3 order to three phases of the system (eg: U,V and W terminals 

    of three-phase instrument).

c. Press down “ON” button, UT261B power indicator illuminates, release it, the button springs up automati

    -cally and the indicator turns off. Therefore you need to press down “ON” button in order to begin the test. 

    When ON is pressed down, “Clockwise” (R) or “Counter-clockwise” (L) rotation indicator illuminates, 

    indicating three-phase system is under “Positive” or “Negative” phase sequence.

a. Remove all test leads away from UT261B;

b. Place UT261B towards the motor, in parallel with motor shaft. The bottom of the instrument should face the 

    shaft (namely, UT261B is located in a direction contrary to that of the motor). Refer to Figure 1 for motor 

    location indicator.

c. Press “ON” button, power indicator illuminates and the test begins. “Clockwise” (R) or “Counter-clockwise” 

    (L) rotation indicator illuminates, indicating the motor is rotating in a “clockwise” or “counter-clockwise”  

    direction.See Figure 2 for details.