background image

UT-501/502 

RS-422/RS-485 Photoelectric Isolation 

Data Repeater 

User

s Manual 

 

 

 

I

General introduction: 

        U T 5 0 1 -

data  repeater  is  a  kind  of  data  relay 

communication  product  of  photoelectric  isolated   
RS-422/RS-485.  It  can  be  used  with  ATC-108 
Photoelectric 

Isolation 

Interface 

Converter 

in 

combination. UT-501 data repeater can prolong the 
communication  distance  of  RS-422/RS-485  bus 
network  and  increase  the  number  of  RS-422/RS-485 
bus  network  devices.  The  inner  circuit  of  ATC-109N 
Photoelectric  Isolation  Data  Repeater  can  detect  data 
direction  and  switch  to  control  it  automatically, 
conveniently  to  form  a  RS-485  network  without  any 
shake  hand  signal.  This  kind  of  RS-485  control  is 
fully transparent and need not amend software for the 
former  network  basing  on  RS-422/485  working 
modes. The built in photoelectric isolator and DC/DC 
converter  can  offer  3500V  isolation  voltage  and  the 
rapid  Transient  Voltage  Suppressor  (TVS)  can 
effectively inhibit lightning and ESD, provide 1000W 
lightning  strike  and  surge  protection  power  on  each 
line,  and  prevent  lightning  strike  and  common  code 
interference. 

II

Performance parameter 

1.  Interface  feature:  interface  is  compatible  with 
EIA/TIA RS-485/RS-422 standard   

2.  Electric  interface:  RS-422/RS-485  interfaces  are 
DB9 interfaces 

3. Transmission media:  twisted-pair cable or shielded 
cable 

4. Working mode: asynchronous half or full duplex 

5. Signal indication: 3 signal indication lights indicate 

TXD, RXD and PWR   

6.  Isolation:  isolation  voltage  3500VRMS  500VDC 

sequence 

7. Transmission speed: 115.2K BPS to 1.2KM 

                                      38.4K BPS to 2.4KM 

 

 

      9600 BPS to 5KM 

8. Protecting grade: RS-422, RS-485 interface 1000W 

lightning strike and surge protection on each line   

9. Extended distance: 0-5 kilometers   

(115200-9600BPS)   

10. Size: 125mmx54mmx25mm 

11.  Working  environment:  -25

  to  70

,    5%  to 

95% relative humidity 

III. Circuit function block diagram: 

 

IV.Connector and signal 

RS-422/485 Pinout: 

(6-bit terminal from the left to right) )                   

Terminal 

No 

RS-422 

T+ 

T- 

R+ 

R- 

VIN 

GND 

RS-485 

485+ 

485- 

VIN 

GND 

V. Installation setup and application: 

Please  read  the  User

s  Manual  carefully  before 

installing  U T - 5 0 1   Photoelectric  Isolation  Data 
Repeater. Connect the product

s power converter with 

+9V socket. The Termnal pin shall be connected with 
RS-422  or  RS-485  network  equipments  according  to 
definition instruction. 
        U T - 5 0 1  Photoelectric Isolation Data Repeater 
supports following 3 relay communication modes:   
1. RS-422/ 4 wire full duplex relay 
2. RS-485/ dual-line half duplex 
3. 4 wire RS-485 to 2 wire RS-485 relay 

RS-422 to RS-422 relay: 

RS-485 to RS-485 relay:

 

4 wire RS-485 to 2 wire RS-485 relay:   

VI. Sketch map for communication connection   

1.  RS-422 4 wire full duplex data relay 
 
 
 

 
 
 
 
 
 

2. RS-485 dual-line half duplex data relay 

 

 

 

Reviews: