The UT-70A is a universal digital meter used to measure:
voltage,  current,  resistance,  inductance,  capacitance,
frequency, hFE, temperature and checking the correctness
of diodes operation.

DC voltage measurement:

200 mV ± (0.5% + 1)  @ 100 µV ,
2 V ± (0.5% + 1)  @ 1 mV ,
20 V ± (0.5% + 1)  @ 10 mV ,
200 V ± (0.5% + 1)  @ 100 mV ,
1000 V ± (0.8% + 2)  @ 1 V

AC voltage measurement:

200 mV ± (1.2% + 3)  @ 100 µV ,
2 V ± (0.8% + 3)  @ 1 mV ,
20 V ± (0.8% + 3)  @ 10 mV ,
200 V ± (0.8% + 3)  @ 100 mV ,
750 V ± (1.2% + 3)  @ 1 V

DC current measurement:

20 µA ± (0.8% + 1)  @ 0.01 µA ,
2 mA ± (0.8% + 1)  @ 1 µA ,
200 mA ± (1.5% + 1)  @ 0.1 mA ,
10 A ± (2.0% + 5)  @ 10 mA

AC current measurement:

20 µA ± (1.0% + 3)  @ 0.01 µA ,
2 mA ± (1.0% + 3)  @ 1 µA ,
200 mA ± (1.8% + 3)  @ 0.1 mA ,
10 A ± (3.0% + 7)  @ 10 mA

Resistance measurement:

200 Ω ± (0.8% + 3)  @ 0.1 Ω ,
2 kΩ ± (0.8% + 1)  @ 1 Ω ,
20 kΩ ± (0.8% + 1)  @ 10 Ω ,
200 kΩ ± (0.8% + 1)  @ 100 Ω ,
2 MΩ ± (0.8% + 1)  @ 1 kΩ ,
20 MΩ ± (1.0% + 5)  @ 10 kΩ ,
2000 MΩ ± (5.0% + 10)  @ 1 MΩ

Capacitance measurement:

20 nF ± (2.5% + 5)  @ 10 pF ,
200 nF ± (2.5% + 5)  @ 100 pF ,
2 µF ± (2.5% + 5)  @ 1 nF ,
100 µF ± (5.0% + 4)  @ 100 nF

Summary of Contents for UT70A

Page 1: ...t factor The device must be secured against contact with caustic staining and viscous fluids The device was designed in such a way that it restarts operation when power supply is restored after a break Turn off the device before transporting it Prior to connecting the device to a power source check whether the supplied voltage is consistent with rated voltage specified in the user manual Attention...

Page 2: ...0 5 1 100 µV 2 V 0 5 1 1 mV 20 V 0 5 1 10 mV 200 V 0 5 1 100 mV 1000 V 0 8 2 1 V AC voltage measurement 200 mV 1 2 3 100 µV 2 V 0 8 3 1 mV 20 V 0 8 3 10 mV 200 V 0 8 3 100 mV 750 V 1 2 3 1 V DC current measurement 20 µA 0 8 1 0 01 µA 2 mA 0 8 1 1 µA 200 mA 1 5 1 0 1 mA 10 A 2 0 5 10 mA AC current measurement 20 µA 1 0 3 0 01 µA 2 mA 1 0 3 1 µA 200 mA 1 8 3 0 1 mA 10 A 3 0 7 10 mA Resistance measur...

Page 3: ...3 0 10 10 mH Frequency measurement 2 kHz 10 MHz 0 1 3 1 Hz automatic range change Temperature measurement C 40 0 C 3 4 1 C 0 400 C 1 3 1 C 400 1000 C 2 10 1 C F 40 32 F 3 4 1 F 32 752 F 1 4 1 F 752 1832 F 2 5 1 F hFE Diode test Sound signal of the continuity test Checking TTL logic states RS 232 Main features Large readable LCD display with backlight Aesthetic and solid construction Power supply 9...

Page 4: ... Code UT 70A UNIVERSAL METER UT 70A UNI T DELTA OPTI Monika Matysiak https www delta poznan pl POL 60 713 Poznań Graniczna 10 e mail delta opti delta poznan pl tel 48 61 864 69 60 2022 01 15 UT 70A 4 4 In the kit ...

Reviews: