Unibrain Fire-i 530/550/630/830/850 Operation Manual
Page 53
4.7.
Memory Channel Save / Load
The setting of the camera features (Shutter, Gain, etc) and video mode can be stored in a non-volatile memory. The
camera supports 16 memory channels as per the table below for the user to conveniently save and load different
features as well as video modes. Channel 0 is for factory default and Channels 1~4 are for saving features.
Channels 5~15 are for resolution, mode and frame rate plus saving other features.
Address
Name
Bit
Description
618h
Memory_Save
[0]
Saves the current setting
[1..31]
Reserved
Address
Name
Bit
Description
620h
Mem_Save_Ch
[0]
Factory Default Setting Cannot overwrite
[1..4]
Write Channel for Memory Save for Channel 1 ~ 4
( Only for Features )
[5..15]
Write Channel for Memory Save for Channel 5 ~ 15
(For Features, Format and Mode Save)
Address
Name
Bit
Description
624h
Cur_Save_Ch
[0]
Read and Load Factory Default Setting
[1..4]
Read and Load Memory Channel 1 ~ 4
[5..15]
Read and Load Load Memory Channel 5 ~ 15
User Defined FireWire Register Control
The values saved in the channel are users define; and can be made the default values at power-on. The channels
from 1 to 15 are to be set in the power-on default mode.
Address
Description( bit : msb*)
Read/Write
0xF2F1011C
Power on default memory channel
Bit 0 ~ Bit 3 : power on initial memory channel
Read/Write