background image

Model:

UGC2005

Air Input:

40/90 PSI - 2.75/6 Bar

Air Consumption:

1/2 CFM: 28/56 L/min

Air Input Connection:

1/4” B.S.P

Year of manufacturing:

2013/14

Height:

1020mm

Width:

440mm

Depth:

475mm

Weight:

28kg

Directive 94/9/EC.Marking:

Ex II 2G T6

Certificate Number:

SIRA 03ATEX5252

Model:

UGC2005M

Air Input:

40/90 PSI - 2.75/6 Bar

Air Consumption:

1/2 CFM: 28/56 L/min

Air Input Connection:

1/4” B.S.P

Year of manufacturing:

2013/14

Height:

1020mm

Width:

440mm

Depth:

475mm

Weight:

28kg

Directive 94/9/EC.Marking:

Ex II 2G T6

Certificate Number:

SIRA 03ATEX5252

Model:

UGC3005

Air Input:

40/90 PSI - 2.75/6 Bar

Air Consumption:

1/2 CFM: 28/56 L/min

Air Input Connection:

1/4” B.S.P

Year of manufacturing:

2013/14

Height:

1020mm

Width:

555mm

Depth:

350mm

Weight:

31kg

Directive 94/9/EC.Marking:

Ex II 2G T6

Certificate Number:

SIRA 03ATEX5252

Model:

UGC4005

Air Input:

40/90 PSI - 2.75/6 Bar

Air Consumption:

1/2 CFM: 28/56 L/min

Air Input Connection:

1/4” B.S.P

Year of manufacturing:

2013/14

Height:

1020mm

Width:

710mm

Depth:

350mm

Weight:

47kg

Directive 94/9/EC.Marking:

Ex II 2G T6

Certificate Number:

SIRA 03ATEX5252

Model:

UGC5005

Air Input:

40/90 PSI - 2.75/6 Bar

Air Consumption:

1/2 CFM: 28/56 L/min

Air Input Connection:

1/4” B.S.P

Year of manufacturing:

2013/14

Height:

1020mm

Width:

845mm

Depth:

445mm

Weight:

57kg

Directive 94/9/EC.Marking:

Ex II 2G T6

Certificate Number:

SIRA 03ATEX5252

Manufactured By:

Unic International UK, Colwick Rd, Nottingham NG2 4BG

Summary of Contents for UGC2005

Page 1: ...hould come with Also available Installation fittings We also recommend I N T E R N A T I O N A L T h e p r o f e s s i o n a l s c h o i c e Solvent Based Spray Gun Cleaner Operating Instructions UGC2005 UGC2005M UGC3005 UGC4005 UGC5005 786 Air Dirt Water trap 783 Nipple FRA3 3 Angle Flange FR3 3 Angle Flange Flat F6R5 6 to 5 Reducer FF3 3 Flange Flat F5R3 5 to 3 Reducer FD3 3 Flexi Ducting Gate V...

Page 2: ...ted area The extraction outlet will accept 3 75mm hose and should be connected to an existing system or taken to the external part of a building and vented via the atmosphere Hose and a range of adaptors are available direct from Unic International The machine will take 20 25 or 30 litre solvent containers When installing 25 30 litre containers we advise that you raise the adjustable corner legs C...

Page 3: ...6mm nylon tube with wire clip in to the full 5 litre container Repeat this step for UGC5005 Turn drain valve lever to vertical position see diagram 2 Underneath the machine at the rear are the earthing wire s the crocodile clip s must be attached to any metal solvent container s if used these are not supplied by Unic international 1 2 3 4 5 6 7 MAINTENANCE CHECK Grid Filter It is recommended that ...

Page 4: ...ion 1 Close lid UGC4005 and UGC5005 ONLY Ensure mode valve control lever is in the automatic position horizontal Turn timer knob clockwise The machine will run automatically for approximately 4 minutes Upon completion open the lid and remove the spray guns from the machine We advise that you DO NOT store the spray guns in the machine MANUAL WASH CLEAN RINSE UGC4005 UGC5005 and UGC2005M For UGC2005...

Page 5: ...he lid was open for removal of the spray gun cups and hoses and just 6 of the limit during the cleaning cycle Substances in the solvent however can be absorbed through the skin see personal protection equipment VENTILATION A local exhaust ventilation system as supplied with the machines should be installed so that vapours are safely vented to atmosphere away from windows and other air inlets In ac...

Page 6: ...0ppm 10 min TWA detection Propan 2 OL 500 ppm Less than limit of Less than limit of Not measured 10 min TWA detection detection Propyl Acetate 250 ppm Less than limit of Less than limit of Not measured 10 min TWA detection detection Butyl Acetate 200 ppm Less than limit of 30ppm 10ppm 10 min TWA detection Xylene 150 ppm Less than limit of 20ppm 150ppm 10 min TWA detection Toluene 150 ppm 3ppm 10pp...

Page 7: ...ized standards Certified to Atex standards Certificate number SIRA 03ATEX5252 EC Notified Body not applicable Approved By Date Director Signed Date Director Printed I N T E R N A T I O N A L T h e p r o f e s s i o n a l s c h o i c e Unic International Colwick Road Nottingham NG2 4BG England Tel 44 0 115 947 4000 Fax 44 0 115 950 6666 Email info unic co uk Web www unic co uk Declaration of Confor...

Page 8: ...CFM 28 56 L min Air Input Connection 1 4 B S P Year of manufacturing 2013 14 Height 1020mm Width 555mm Depth 350mm Weight 31kg Directive 94 9 EC Marking Ex II 2G T6 Certificate Number SIRA 03ATEX5252 Model UGC4005 Air Input 40 90 PSI 2 75 6 Bar Air Consumption 1 2 CFM 28 56 L min Air Input Connection 1 4 B S P Year of manufacturing 2013 14 Height 1020mm Width 710mm Depth 350mm Weight 47kg Directiv...

Page 9: ... A L T h e p r o f e s s i o n a l s c h o i c e Information Request Form FAX BACK 44 0 115 950 6666 Please send information on please tick appropriate box Mini Spray Gun Cleaners Can Crushers Paint Can Washers Paint Can Shakers Brake Washer Parts Washer Solvent Recycler Spares Service Information Other Comments Please send this information to Name Address Email Telephone Fax ...

Page 10: ...ctions as to the storage installation commissioning use or maintenance of the Machine or if there are none good trade practice or d the Buyer alters or repairs the Machine other than by replacing consumable items such as filters jets and flow through brush or such units as are intended to be replaced by the user as specified in the manual without the written consent of the Company or f any parts n...

Reviews: