Test Report

on emissions from Powerclean Spray Gun Cleaners

Table 3

- Solvent concentrations measured during the operation of a Unic Powerclean Automatic Spray

Gun Cleaning Machines.

*a

This monitoring position was outside the operator’s breathing zone. Measurements were taken
to establish the effectiveness of the ventilated enclosure.

*b

Exposure limits are generally for single compounds. Where there is reason to believe that
effects are additive a mixed exposure is assessed using the formula: C1/L1+ C2/L2...< 1
where C1 etc. are the measured concentrations and L1 etc are the corresponding exposure
limits.

Solvent

Acetone

1500 ppm

Less than limit of

50ppm

50ppm

(10 min. TWA)

detection

Propan - 2 - OL

500 ppm

Less than limit of

Less than limit of

Not measured

(10 min. TWA)

detection

detection

Propyl Acetate

250 ppm

Less than limit of

Less than limit of

Not measured

(10 min. TWA)

detection

detection

Butyl Acetate

200 ppm

Less than limit of

30ppm

10ppm

(10 min. TWA)

detection

Xylene

150 ppm

Less than limit of

20ppm

150ppm

(10 min. TWA)

detection

Toluene

150 ppm

3ppm

10ppm

60ppm

(10 min. TWA)

White Spirit

720mg/m3

30mg/m3

75mg/m3

100mg/m3

(10 min. TWA)

% of mixed exposure

100%

6%

49%

156%

limit *b

(10 min. TWA)

Short Term

Exposure Limit

Ref: EH 40 1992

Monitoring

Position 1

10cm above the

unit during normal

operation.

Lid closed.

Ventilation off.

Monitoring

Position 2

10cm above the

unit when the cycle

had finished.

Lid open.

Ventilation on.

Monitoring

Position 3

*a

inside the enclosure

when the cycle had

finished.

Lid open.

Ventilation on.

Summary of Contents for UGC2006M

Page 1: ...ngs We also recommend I N T E R N A T I O N A L T h e p r o f e s s i o n a l s c h o i c e Solvent Based Spray Gun Cleaner Operating Instructions UGC2006M UGC2006 UGC4006 UGC5006 786 Air Dirt Water t...

Page 2: ...re Hose and a range of adaptors are available direct from Unic International Connect the machine to the air supply All air connections are located on the right hand side of the machine when viewed fro...

Page 3: ...f solvent and enter drain tube Push solvent container s under machine aligning filler neck with male part of quick release coupling Reconnect quick release coupling UGC4006 UGC5006 ONLY Place the full...

Page 4: ...y 4 minutes Upon completion open the lid and remove the spray guns from the machine We advise that you DO NOT store the spray guns in the machine MANUAL WASH CLEAN RINSE UGC4006 and UGC5006 For UGC200...

Page 5: ...e lid was open for removal of the spray gun cups and hoses and just 6 of the limit during the cleaning cycle Substances in the solvent however can be absorbed through the skin see personal protection...

Page 6: ...ppm 10 min TWA detection Propan 2 OL 500 ppm Less than limit of Less than limit of Not measured 10 min TWA detection detection Propyl Acetate 250 ppm Less than limit of Less than limit of Not measured...

Page 7: ...nized standards Certified to Atex standards Certificate number SIRA 03ATEX5252 EC Notified Body not applicable Approved By Date Director Signed Date Director Printed I N T E R N A T I O N A L T h e p...

Page 8: ...turing 2013 14 Height 1525mm Width 526mm Depth 400mm Weight 47kg Directive 94 9 EC Marking Ex II 2G T6 Certificate Number SIRA 03ATEX5252 Model UGC4006 Air Input 40 90 PSI 2 75 6 Bar Air Consumption 1...

Page 9: ...A L T h e p r o f e s s i o n a l s c h o i c e Information Request Form FAX BACK 44 0 115 950 6666 Please send information on please tick appropriate box Mini Spray Gun Cleaners Can Crushers Paint Ca...

Page 10: ...s as to the storage installation commissioning use or maintenance of the Machine or if there are none good trade practice or d the Buyer alters or repairs the Machine other than by replacing consumabl...

Reviews: