“SIC FAIL”
: stove overheating
When the text “SIC FAIL” appears, the pellet gearmotor blocks and the stove enters the
extinction phase.
Th e stove can be restarted by rearming the thermostat as shown in fi gure 3.
Th e manual rearm button is located at the back of the stove (5).
Unscrew the protective cap and press the button below all the way.
In case of further blocks caused by the same problem, do not try to rearm the stove and
contact the Authorised Service Centre.
Fig. 3: manually rearmed
thermostat
1. On-off Switch
2. Power cable
3. Fuse F4AL250V
4. PC connection (optional)
5. Th ermostat rearm button
6. Room temperature probe
Medium mod.
1
2
3
5
4
6
Large mod.
1
2
4
3
5
6
5
6
3
4
1
2
EXTINCTION ALARM DURING WORK
Triggered when the stove extinguishes during the work phase (e.g.: pellets in tank fi nished).
Th e display reads
NO FIRE. Press the key to reset the alarm
Empty the brazier and perform another ignition.
FLUE GAS PROBE ALARM
Triggered when the fl ue gas detection probe fails or is disconnected. Th e display reads
sond
fumi [fl ue gas probe], Contact the Authorised Service Centre.