8
ATTENTION!
Before ignition, a bit of smoke could fill the combustion chamber.
!
3.2 Stove extinction
To switch off the stove, press the key
until the display reads “OFF”. Even after extinction of the stove, the
flue gas extractor fan will continue running for a preset amount of time to guarantee quick exhaust of the flue
gas from the combustion chamber.
4.1 Programming stove - chronothermostat (optional)
This function allows you to program two ignitions and two extinctions of the stove during the day or to pro-
gram it weekly.
To enter programming:
• Press the key
SET
twice;
• Select the submenus (UT) using the keys
and
.
UT01
: Setting current day and switching chronothermostat off.
If the parameter UT01 is set with the current day, for example Sunday (Day 7), select the day of the week to
which to associate PROGRAM 1 and/or PROGRAM 2 ignition.
Change output
It can be changed while the stove is working from a minimum of 1 and a maximum of 5. Press the button
to increase the value and the button
to decrease it. The display indicates the output value.
Change temperature
The user can change the temperature at any time. To change the temperature, first press
SET
and then press
or
and select the desired value, which will appear on the lower display.
• After a few minutes, the upper display will read “ON 1-2-3-4-5” according to the output set, while the lower
display will show the room temperature;
• When the set temperature is reached, the upper display will read: “ECO” while the detected room temperature
will appear on the lower display;
• The temperature LED switches on when the set temperature is reached;
• Before lighting the stove, make sure that the brazier is clear of pellets and clean from residues of previous
combustion. Otherwise empty and clean it;
ATTENTION:
the brazier must be cleaned daily and the ash pan periodically. Reduced
or lack of cleaning can cause the stove to fail to ignite, damaging the stove
and the environment (possible emissions of non-combusted material and
soot).
Do not put pellets back into the brazier when they did not light.
!
4.0 Adjusting the stove