User’s operating instructions

A = Manometer
B = Summer/Winter Heating temperature controller
C = D.H.W. temperature controller
D = Push button for RESET/CALIBRATION/DIAGNOSTICS
E = Display
F = Symbol indicating a heating request
G = Symbol indicating a D.H.W. request
I

= Symbol indicating a burner lockout

L = Symbol indicating burner in operation
M = Symbol indicating an error presence
N = Digits indicating boiler temperature or error code

B

D

A

C

E

F
G

L

I

M

N

Summer/Winter Heating temperature
controller

Through this knob it is possible to select the
operation mode:
·

Summer (D.H.W. production only)

·

Winter (Heating and D.H.W. production)

The pointer of the knob in 

Summer position

means that the boiler does not supply any
heating (in any case the anti-frost protection
remains active).

With the pointer of the knob within the range
shown beside, the boiler is in Winter mode
and controls the heating water temperature,
which can be adjusted between a minimum
of 30°C and a maximum of 85°C.

D.H.W temperature controller

In the ALKON R models this function is active only if the boiler
is connected to an external D.H.W. storage tank.

Through this knob it is possible to adjust the
temperature of the D.H.W.

NOTE
In the ALKON R models, not
connected to an external
D.H.W. storage tank, the
pointer of the knob has to be
positioned as shown beside.

With the pointer of the knob within the range
shown beside, the D.H.W. temperature is 38°C.

Function “ECO-COMFORT”

With the pointer of the knob within the range
shown beside, there is the activation of the
function ECO-COMFORT, which assures a
drawing of D.H.W. at 38°C with the best energy

saving.

Function “COMFORT”

The D.H.W. temperature can be adjusted
between a minimum of 38°C and a maximum
of 60°C.

HOLIDAYS

If the boiler is not controlled by a modulating
chrono-thermostat, during Holidays period the
pointer of the knob has to be positioned within
the range shown beside.

°C

®

MAX

MAX

M

IN

MAX

MAX

MAX

MAX

MAX

MAX

6 - OPERATING  INSTRUCTIONS

6.1 - CONTROL PANEL

Summary of Contents for Alkon 09 R 18

Page 1: ...00333177 1st edition 06 2009 ALKON 09 R 18 C 18 R 24 C 24 USER SOPERATING INSTRUCTIONS ...

Page 2: ...or it is essential to carefully follow the instructions indicated in this guide 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned In hard water areas where the main water can exceed 15 f total hardness a scale reducing device is recom mended The choice of this device has to be made taking into consideration the water s charac...

Page 3: ...e held liable for any such injury and or damage 4 INFORMATION TO BE HANDED OVER TO THE USER BY THE INSTALLER 5 SAFETY WARNINGS WARNING The installation adjustment and servicing of this appliance must be carried out by a competent person and installed in accordance with the current standards and regulations Failure to correctly install this applian ce could cause injury to persons animals or damage...

Page 4: ...ng water temperature which can be adjusted between a minimum of 30 C and a maximum of 85 C D H W temperature controller In the ALKON R models this function is active only if the boiler is connected to an external D H W storage tank Through this knob it is possible to adjust the temperature of the D H W NOTE In the ALKON R models not connected to an external D H W storage tank the pointer of the kn...

Page 5: ...s shown flashing on the display Reset button By pressing this push button it is possible To restart the boiler after a lockout due to the burner control which has lit on the display the symbol To have the error code shown on the display if the boiler operation was not stopped by this fault To activate the special function for calibration To enter the Service Menu and select the parameters Indicati...

Page 6: ...mostat position the pointer of the knob B in an intermediate position During the operation in C H mode on the display the actual boiler water temperature and the symbol are shown Put out of operation In order to put completely out of operation the boiler cut the power supply to the boiler through the external main switch In case of long periods of inactive state of the boiler close also the gas an...

Page 7: ...r Sales Service Centre C Error code Meaning Too low water pressure in the C H circuit Elimination of the fault Restore the correct pressure value by regulating the boiler s filling valve for correct boiler operation the pressure should be between 0 8 and 1 bar When the correct pressure value has been reached the led will switch off automatically and normal boiler operation will be restored DANGER ...

Page 8: ...al ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Reviews: