19
ENGLISH
Installation Instructions
3.6 - FlUE GAS EXhAUST PIPE
CONNECTION
To connect the flue gas exhaust pipe, local and national stand
-
ards must be observed
In the event the boiler is replaced, AlWAYS replace the flue
gas pipe as well.
The boiler is type approved for the exhaust configurations listed
below:
B23P
TOTAL LENGTH (LS)
SINGLE Ø120
FROM [m]
TO [m]
1
20
Connection to a combustion products evacuation pipe outside
the room; the combustion air is taken directly from the room
where the appliance is installed.
c63x
c63
Boiler intended for connection to a combustion air intake and
combustion products evacuation system, approved and sold
separately
ATTEnTIOn:
The flue must comply with standards
in force.
NOTE!
For more information
See Technical Info
from site indicated at pag. 2
Ø 120 optional adapters for twin flue
systems