21
Instruction for the installer
KIT5750C
KIT5760C
KIT0590C
SMOKE EVACUATION Ø80 mm with AIR INTAKE FLANGE - Installation type B23
The maximum allowed virtual length for the smoke
evacuation duct is 20 m, included one wide radium curve
and one evacuation terminal.
For this type of installation the smoke
evacuation duct has to be independent.
KIT5720C
TSC0130C
TSC0150C
KIT5770C
WARNING: The combustion air is taken from
the room where the boiler is installed. If the
boiler is installed in an unventilated room,
convenient ventilation openings need to be
done.
For installations where there is the freezing risk, it is
suggested to insulate the smoke evacuation duct Ø80 mm in
all its length, even if its layout is within a chimney.
00361446
Fit the rubber spacer, supplied with the
boiler, as shown in the picture.