Installation Instructions
(FA) Factory Parameters
ACTIVATION - SELECTION See section 1 (4.2)
Press rest button
(D)
to access the FA param-
eters unit. These parameters can be edited by
entering the ACCESS CODE.
service
D
ACCESS CODE
Use knobs to dial the code (
B
- TENS) - (
C
UNITS)
Confirm with the reset button
(D)
Once the access code has been entered, Fac-
tory parameter units are displayed
2
DISPLAY
Turn knob (
B)
to scroll the parameters.
3
UNIT 1 - FA PARAMETERS LIST
CODE
RANGE DESCRIPTION
Gt
0
1
Type of Gas
0 = methane (default)
1 = GPL
PL
15 100
Minimum pump modulation
level *
Pr
20 100
Maximum pump modula-
tion level
dt
5 20
Pump temperature differ
-
ential
SP
0
6
Pump pause time during
CH / DHW service change
and vice-versa
0 = no pause
1÷6 = Time in seconds
AP
1
4
1: Instantaneous boiler
2: Instantaneous boilers
with
fixed hysteresis
3: Heat. only boiler / or
storage tank (1 pump +
1 3-way val.)
4: Boiler with storage tank
2 pumps
PS
0
1
Heat. pressure sensor
0 = absent / 1 = present
(default 0)
PA
15 60
Ignition air pressure
(default 30)
oA
0 60
Offset Air (default 20)
rP
0
1
Primary
D
t protection
0 = disabled
1 = enabled
(default 1)
bP
1
9
Type boiler / Power
(befault 1)
AL
0
1
Function antilegionella
storage tank boiler (w3/W4)
Hr
0 10
Mantenimento richiesta
sanitaria
hP
1 20
Heating control:
proportional
hl
1 20
Heating control:
integrative
hd
1 20
Heating control:
derivative
dP
1 20
Domestic hot water
control: proportional
dl
1 50
Domestic hot water
control: integrative
dd
1 20
Domestic hot water
control: derivative