43
ENGLISH
Installation Instructions
MAX
++
+
-
14.1
service
=
MIN
MAX
x 2’’
service
MIN
Pressure MIN P0
MAX
IN
M
MAX
MIN
service
service
+
-
6.0
Turn the
‘’C‘’
knob to the MAX and press the
‘’D‘’
button more time until it is close to the desired value
(eg. 82 red on display, which corresponds to 14.1 read on the pressure gauge).
NOTE: do not exceed the target of (max + 0,2 mbar) and carry out the adjustment in RISE (the valve
gas works better with ever increasing correction).
If the value read on the pressure gauge (eg 14.1) is satisfactory,
SET:
Turn the
‘’C‘’
knob to the INTERMEDIATE position and press the
‘’D‘’
button for about 2 seconds
(the new value will flash indicating new storage).
Turn knob
B
to MIN, the display will show
P0
and the modulation will drop to the minimum preset.
Wait few seconds for the pressure value to stabilize. Read the pressure value MIN on the pressure gauge
and compare it with the value in the table NOZZLES PRESSURE Chap. 4.2 (eg 1.2).
Considering the example shown in the figure, having to calibrate the valve at 1.7 mbar can be concluded
that this is a VALUE TOO LOW therefore: