Instructions for the User

Pressure of the C.H. system

In case the C.H. system is of open expansion vessel type,
there is no need of reinstatment of the pressure, because
this is automatically done via the expansion vessel per-
manently connected to the C.H. system.

In case the C.H. system is of closed expansion vessel
type,(

see the local rules to ascertain this possibility)

,

the system pressure will be reinstated, via the filling val-
ve, at a value, 

with cold system

, of 1.0 /1.2 bar.

In case repeated reinstatment interventions are re-
quired, check the C.H. system for water leaks.

6 - INSTRUCTIONS FOR THE USE

6.1 - CHECKS TO BE PERFORMED BEFORE

PUTTING THE BOILER IN OPERATION

Before putting the boiler in operation it is suggested to
perform the following checks:

-

Make sure that, after a service work, the flow and re-
turn gate valves are open.

-

Ascertain that the discharge of the safety valve, in case
of closed expansion vessel type, is connected to the
sewage.

-

Ascertain the good operation of the smoke by-pass,
by placing an electrical torch in the smoke chamber,
through the cleaning door and looking from the wood
loading door: no light shoul de seen.

WARNING !

The C.H. system can be conveniently protected from fre-
ezing by adding an antifreeze product, suitable for multi-
metal C.H. system.

Do not use antifreeze products suitable for engines,
because they can damage the sealing gaskets of the
C.H. system.

6.2 - STARTING

Make sure that all the checks listed on paragraph 6.1 have
been performed.

Place, in the center of the grate, thin paper (newspapers
etc.) and a little thin and dry wood, cross disposed; avoid
large pieces in the shape of squares

Open the rear by-pass

Light the paper and close the upper door. Wait for the fire to
start and produce the embers (5 to 10 minutes).

After that, looking through the secondary air inlet on the
upper door, the flame will be noticed .

Important: The by-pass should be used only at the start
and during subsequent loading,

 

During the operation,

the by-pass should always be tightly closed

1st LOADING

When the bed of embers is formed on the grate, it is possible
to proceed to the loading of the wood

Open slowly  the upper door.
Spread the embers uniformly on the grate, using the poker.

The wood must be of the following length:

a) 33 cm (+ 1 cm - 4 cm) for the model FOKOLUS 20
b) 50 cm (+ 1 cm - 4 cm) for models FOKOLUS 30
c) 70 cm (+ 1 cm - 4 cm) for the model FOKOLUS 40

These dimensions must be strictly observed.

to cut

Summary of Contents for FOKOLUS

Page 1: ...USER S INSTRUCTIONS 00333935 Ed 12 2010 FOKOLUS ...

Page 2: ...se of this appliance will be considered improper UNICAL declines any responsibility for any damages or injuries caused by an improper use in this case the risk is completely at the user s responsibility In order to use the appliance according to the foreseen scopes it is necessary to carefully follow the instructions indicated in this manual 3 WATER TREATMENT In hard water areas where the main wat...

Page 3: ...e manual always follows the appliance so that it can be consulted by the new owner and or installer Failure to follow the instructions indicated in this guide which is supplied with the boiler could cause injury to persons animals or damage to property The manufacturer shall not be held liable for any such injury and or damage 4 INFORMATION TO BE HANDED OVER TO THE USER 5 SAFETY WARNINGS WARNING T...

Page 4: ...ing door no light shoul de seen WARNING The C H system can be conveniently protected from fre ezing by adding an antifreeze product suitable for multi metal C H system Do not use antifreeze products suitable for engines because they can damage the sealing gaskets of the C H system 6 2 STARTING Make sure that all the checks listed on paragraph 6 1 have been performed Place in the center of the grat...

Page 5: ...y air adjustment is done automatically through the thermostatic valve the secondary air however done through the port located on the upper loading door must be done by the user tightening or loosening the adjustment screw At the first start it is necessary to adjust the primary and the secondary air and bearing in mind that the primary air determines the boiler output and therefore the amount of w...

Page 6: ...nsation black liquid on the floor behind the boiler In this case a less humid wood shall be used check the operation of the recircu lation pump the smoke temperature at part load and increase the working temperature To control the room temperature it is then necessary to install a mixing valve The corrosion due to condensation of the smokes is not covered by the gua rantee because due to the wood ...

Page 7: ... of combustion accumulated in the wood storage Clean with the brush supplied the upper smoke dry passages of the furnace Remove the ashes accumulated in the smoke chamber through the rear cleaning door Make sure that the slots of the grate are not clogged and if they are make free the slots with the poker s help Every month Check the operation of the by pass and its tightness as described in chapt...

Page 8: ...ed the wood storage the formation of bridges is observed Remedy Check the length of the logs see chap 6 6 Check the arrangement of the logs see chap 6 6 Cut the logs in half see chap 6 6 Use the smaller sized logs round or squares about 5 7 cm wide Mix the medium large size logs round or squares of 15 20 cm per side with small logs see above Symptom The boiler does not reach the temperature the fl...

Page 9: ...Easy replacement spare parts ...

Page 10: ...ease contact our Authorized Service Center COMPONENT 95900056 6 X 95900057 Sealing gasket for cleaning door ø 95x3 6 X 95900058 X FOKOLUS 30 m 1 6 X m 1 7 FOKOLUS 40 m 1 6 X m 1 7 X X X X X X X X X X X X X X X X X X X X X 7 7 7 8 8 8 9 10 11 12 12 12 95900622 95900852 95901020 31418 95900362 31045 MAN0020 95900862 PUC0420 32762 95900523 95900863 Kit of curved tiles Kit of curved tiles Kit of curve...

Page 11: ...Notes ...

Page 12: ...al ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...