background image

5

Instructions for the User

Since for a good combustion it is essential that there is an
uniform falling down of the firewood, it is necessary to make
sure that the length of the introduced wood logs, their form
and the way of loading don’t prevent the regular descent of
the fuel.

The wood logs must be placed longitudinally and
horizontally. No log has to be placed slanting or athwart.

SUBSEQUENT LOADINGS

Before making a new loading of wood, consume, as much as
possible, the previous one.

The new loading will be done when the bed of embers, on the
grate, will be reduced to a thickness of about 5 cm.
Open slowly  the upper loading door.
Use only wood logs having a length as stated in the previous
paragraph.
Place the new loading of wood as above described.

USEFUL SUGGESTIONS AND LOADING ERRORS

- Too long logs do not fall down regularly and can cause
“bridges”.

- Too short logs cause not regular air passages, with
consequent reduction of output and efficiency.

- In case the quality of the wood causes “bridges” it could be
necessary to cut the wood logs in two parts, as stated in the
paragraph FIRST LOADING.

- Open the upper door always slowly, in order to avoid
blowbacks and smoke formations.

6.3 -

COMBUSTION AIR ADJUSTMENT

ADJUSTMENT OF PRIMARY AND SECONDARY AIR

The boiler FOKOLUS is equipped with primary
air (pos 5, fig. 1) and secondary air adjustment
(pos 4,Fig. 1). The primary air adjustment is
done automatically through the thermostatic
valve; the secondary air, however, done through
the port located on the upper loading door, must
be done by the user, tightening or loosening the
adjustment screw.

At the first start it is necessary to adjust the primary and the
secondary air and bearing in mind that the primary air
determines the boiler output, and therefore the amount of
wood that is burned, and the secondary air completes the
combustion.

The optimal setting of the FOKOLUS operation is obtained
when boiler and chimney  are in “warm conditions”.

GENERAL SUGGESTIONS

- Best performances are obtained after two/three days of ope-

ration. Refractory material must be cooked.

- The flame should have a good size and fairly fill the firebox.
- The flame should not be too red (insufficient secondary

air S).

- If the chimney is smoking too much (open all the secondary

air S).

- If it continues smoking, give maximum of secondary air.

Example No. 1

Big wet wood logs of difficult combustion:
SECONDARY AIR:  Very closed (try to get the maximum size
of the flame, but not of the red color).

Example No. 2

Highly flammable wood logs
SECONDARY AIR:  - Completely open.

6.4 -

CHECKS TO BE CARRIED OUT AFTER
THE FIRST START

CHECKING OF THE SEALS

During the initial start-up check the tightness
of the smoke circuit and the connection to the
chimney . If there is any noticeable smoke
leaks alert the installer and / or the After Sale
Service.

If there is any noticeable air suction through the door seals,
tighten the handle with greater force.

Check for water leaks from pipe connections.

Summary of Contents for FOKOLUS

Page 1: ...USER S INSTRUCTIONS 00333935 Ed 12 2010 FOKOLUS ...

Page 2: ...se of this appliance will be considered improper UNICAL declines any responsibility for any damages or injuries caused by an improper use in this case the risk is completely at the user s responsibility In order to use the appliance according to the foreseen scopes it is necessary to carefully follow the instructions indicated in this manual 3 WATER TREATMENT In hard water areas where the main wat...

Page 3: ...e manual always follows the appliance so that it can be consulted by the new owner and or installer Failure to follow the instructions indicated in this guide which is supplied with the boiler could cause injury to persons animals or damage to property The manufacturer shall not be held liable for any such injury and or damage 4 INFORMATION TO BE HANDED OVER TO THE USER 5 SAFETY WARNINGS WARNING T...

Page 4: ...ing door no light shoul de seen WARNING The C H system can be conveniently protected from fre ezing by adding an antifreeze product suitable for multi metal C H system Do not use antifreeze products suitable for engines because they can damage the sealing gaskets of the C H system 6 2 STARTING Make sure that all the checks listed on paragraph 6 1 have been performed Place in the center of the grat...

Page 5: ...y air adjustment is done automatically through the thermostatic valve the secondary air however done through the port located on the upper loading door must be done by the user tightening or loosening the adjustment screw At the first start it is necessary to adjust the primary and the secondary air and bearing in mind that the primary air determines the boiler output and therefore the amount of w...

Page 6: ...nsation black liquid on the floor behind the boiler In this case a less humid wood shall be used check the operation of the recircu lation pump the smoke temperature at part load and increase the working temperature To control the room temperature it is then necessary to install a mixing valve The corrosion due to condensation of the smokes is not covered by the gua rantee because due to the wood ...

Page 7: ... of combustion accumulated in the wood storage Clean with the brush supplied the upper smoke dry passages of the furnace Remove the ashes accumulated in the smoke chamber through the rear cleaning door Make sure that the slots of the grate are not clogged and if they are make free the slots with the poker s help Every month Check the operation of the by pass and its tightness as described in chapt...

Page 8: ...ed the wood storage the formation of bridges is observed Remedy Check the length of the logs see chap 6 6 Check the arrangement of the logs see chap 6 6 Cut the logs in half see chap 6 6 Use the smaller sized logs round or squares about 5 7 cm wide Mix the medium large size logs round or squares of 15 20 cm per side with small logs see above Symptom The boiler does not reach the temperature the fl...

Page 9: ...Easy replacement spare parts ...

Page 10: ...ease contact our Authorized Service Center COMPONENT 95900056 6 X 95900057 Sealing gasket for cleaning door ø 95x3 6 X 95900058 X FOKOLUS 30 m 1 6 X m 1 7 FOKOLUS 40 m 1 6 X m 1 7 X X X X X X X X X X X X X X X X X X X X X 7 7 7 8 8 8 9 10 11 12 12 12 95900622 95900852 95901020 31418 95900362 31045 MAN0020 95900862 PUC0420 32762 95900523 95900863 Kit of curved tiles Kit of curved tiles Kit of curve...

Page 11: ...Notes ...

Page 12: ...al ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Reviews: