8
Instructions for the User
6.8 -
FAULT REMOVAL
Symptom:
- When opening the loading door blowbacks and smoke
leaks occur.
Remedy:
- Open slowly.
- Use less dry wood logs; make sure the boiler does not
make long stops (see chap. 5.9).
- Use thicker wood logs.
- Consume the previous charge before making a new one.
Symptom:
- The boiler does not reach the temperature. The flame is
small, with air excess.
Inspected the wood storage, the formation of bridges is
observed.
Remedy:
- Check the length of the logs (see chap. 6.6).
- Check the arrangement of the logs (see chap. 6.6).
- Cut the logs in half (see chap. 6.6).
- Use the smaller-sized logs (round or squares about 5-7 cm
wide).
- Mix the medium-large size logs (round or squares of 15-20
cm per side) with small logs (see above).
Symptom:
- The boiler does not reach the temperature, the flame is
very small.
Remedy:
- Check the closing of the by-pass.
- Check the closing of the doors.
Not getting results, refrain from further
action and contact an authorized Unical
service center
Summary of Contents for FOKOLUS
Page 1: ...USER S INSTRUCTIONS 00333935 Ed 12 2010 FOKOLUS ...
Page 9: ...Easy replacement spare parts ...
Page 11: ...Notes ...