23 THE INSTALLATION OF THE DEVICE
1. VERZIÓ RU
The following rules must be abided by upon the
execution of the electric connections:
1.
Connect the mains cable in a polarity-correct way
to the electric mains. The maximum length of this
can be 3 m.
2.
The markings upon connection: L – phase
conductor, N – neutral conductor.
3.
The recommended cross-section of the connecting
cables is 1.5 mm
2
, and it is to be damage-free hose
conductor.
4.
Connection is to be performed according to the
electric switching diagram.
5.
The connection of a protective conductor is
obligatory.
Gas and water pipes must not be used for the
protective wire! The boiler and the pipe system
are to be connected with the shock-proofing
system with a standard protective conductor.
The manufacturer undertakes no responsibility
for incorrect execution!
GAS CONNECTION
The device can be connected either to a piped natural
gas or tanked gas (LPG) system.
Before you execute the connection, the following is to be
performed:
o
Check what gas type the boiler has been regulated
for and what is at disposal upon connection.
o
Check the cleanness of the gas pipe and if
necessary, install a filter in front of the boiler.
The gas connection must ensure gas of the
appropriate quantity and pressure, and the
appropriate operation of the measuring and safety
system must be checked.
After you have connected the device to the gas
system, check whether the seal is intact and
whether the standards have been abided by.
The gas pipe connection size of every GHISS device
type is ¾”.
CONDUCTING COMBUSTION PRODUCTS
Connect the boiler to the chimney according to the valid
standards and requirements.
Connection is to be executed with rigid pipes, providing
for appropriate caulking, also counting on the
condensing water that may be produced. The
mechanical attachment of connecting pipes should be
secured against movement and slipping out.
The boilers are equipped with smoke gas restricting
thermostat, which, in case smoke gas flows back,
close down the operation of the boiler in an
interlocked manner
The use of un-insulated external chimney poses
potential dangers.
The connection of GHISS 16, -24, -32, -40 .. .. type
devices to the chimney.
GHISS 48, -56 .. .. type devices are to be connected to
the chimney with an external deflector.