34
TECHNICAL SPECIFICATIONS
Unit of
measurement
Model HP_OWER ONE
140R-140RK
160RT-160RTK
180RT-180RTK
Electrical data
Power supply
230V/1/50Hz
400V/3P+N+T/50Hz
400V/3P+N+T/50Hz
Maximum input power
kW
6,6
7,0
8,3
Maximum input current
A
28,6
10,1
12,0
Maximum input power (version -K)
kW
6,7
7,1
8,5
Maximum input current (version -K)
A
29,2
10,3
12,2
Dimensions and
weights
A - Length
mm
1044
1044
1044
B - Depth
mm
448
448
448
C - Height
mm
1409
1409
1409
Shipping weight
kg
134
154
154
Operating weight
kg
121
141
141
Dimensions with
packaging
A - Length
mm
1100
1100
1100
B - Depth
mm
490
490
490
C - Height
mm
1605
1605
1605
Performance referring to the following conditions:
(1) Cooling: outdoor air temperature 35°C; in/out water temperature 23/18 °C
(2) Cooling: outdoor air temperature 35°C; in/out water temperature 12/ 7°C.
(3) Heating: outdoor air temperature 7°C DB 6°C WB; in/out water temp 30/35°C.
(4) Heating: outdoor air temperature 7°C DB 6°C WB; in/out water temp 40/45°C.
(5) Cooling: in/out water temperature 7/12°C.
(6) Heating: average climatic conditions; Tbiv=-7°C; in/out water temp 30/35°C.
(7) Indicative data subject to changes. For the correct value, always refer to the technical label on the unit.
(8) Sound power level: full load unit in heating mode according to EU Regulation 813/2013 for medium and low temperature applications. Value determined on
the basis of measurements carried out in accordance with EN 12102-1: 2017, used in conjunction with UNI EN ISO 9614-2 which describes the test with the
Intensimetric method. The tolerance on the value of the total sound power level is 2 dB (A).
(9) Sound pressure level: value calculated from the sound power level using ISO 3744:2010, considering the units in the open field
(*) activating the “maximum Hz” function
Performance data declared in points (1), (2), (3) and (4) is intended to refer to instantaneous power according to UNI EN 14511. The value
declared in point (5) and (6) is determined according to UNI EN 14825.
CAUTION: The minimum temperature allowed for storing the units is 5°C.
12.2
UNIT AND AUXILIARY ELECTRICAL DATA
Unit power supply
V/~/Hz
230/1PH+PE/50*-
400/3PH+PE/50**
Remote controller circuit
V/~/Hz
12/1/50
On board controller circuit
V/~/Hz
12/1/50
Fans power supply
V/~/Hz
230/1/50
For the 70R/RK, 90R/RK, 120R/RK, 140R/RK models * - For 160RT/RTK e 180RT/RTK models **
NOTE: The electrical data are subject to change due to updates. It is therefore always necessary to refer to the technical
specifications label applied on the right side panel of the unit.
12.3
CORRECTIVE FACTORS
DIRTY EXCHANGER WITH WATER / REFRIGERANT PLATES
ALTITUDE:
The performance correction factors according to altitude are calculated by cooling under conditions (2) and for heating under
conditions (3) of the previous technical data tables.
Dirt Factor [m
2
°C / kW]
Correction factor Thermal Power
Correction factor Input Power
0,44 x 10
-1
1,00
1,00
0,88 x 10
-1
0,99
1,00
1,76 x 10
-1
0,98
1,00