background image

3

General information

1.1 -

SYMBOLS USED IN THIS GUIDE

When reading this guide particular care has to be given to the parts marked with the following symbols:

NOTE!
Suggestions for the
user

WARNING!
Indicates a potentially dangerous
situation for the product and the
environment

DANGER!
Indicates serious danger
for your personal safety
and for your life

1.2 - CORRECT USE OF THE APPLIANCE

The water heater IDRONIC has been designed utilizing today’s technology and in compliance with the
current safety regulations.However, following an improper use, dangers could arise for the safety and life
of the user or of other people, or damage could be caused to the appliance or other objects.The appliance
is designed for the domestic hot water production. Any other use of this appliance will be considered
improper.UNICAL declines any responsibility for any damages or injuries caused by an improper use; in
this case the risk is completely at the user’s responsibility.In order to use the appliance according to the
scopes it was designed for it is essential to carefully follow the instructions indicated in this guide.

1.3 -

WATER TREATMENT

The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned.

In hard water areas where the main water can exceed 15°f total hardness, a scale reducing device is
recommended. The choice of this device has to be made taking into consideration the characteristics of the
water.

In order to improve the resistance to lime scale it is recommended to adjust the domestic hot water temperature

as near as possible to the one you really require.

We recommend you to check the state of cleanliness of the heat exchanger at the end of the first year and
subsequently, on the basis of the lime scale found, this period can be extended to two years.

1.4 -

INFORMATIONS TO BE HANDED OVER TO THE USER

1

GENERAL INFORMATION

The user has to be instructed on the use and operation of his D.H.W. system

, in particular:

Hand over these instructions to the end user, together with any other literature regarding this appliance,
placed inside the envelope contained in the packaging. 

The user has to keep these documents in a safe

place in order to always have them at hand for future reference.

Inform the user on the importance of air openings and of the flue outlet system, stressing the fact that it  is
absolutely forbidden to make any alterations to the appliance.

Inform the user how to adjust the correct water temperature in order to save energy.

Remind the user that, in compliance with the rules in force, a comprehensive control and service of the
appliancmust be performed in compliance with prescriptions and with the frequency indicated by the
manufacturer.

If the appliance is sold or transferred to another owner or if the present user moves home and leaves the
appliance installed, ensure yourself that the manual always follows the appliance so that it can be consulted
by the new owner and/or installer.

Failure to follow the instructions indicated in this guide, which is supplied with the appliance, could cause
injury to persons, animals or damage to property.  The manufacturer shall not be held liable for any such
injury and/or damage.

Summary of Contents for IDRONIK TN 14

Page 1: ...00333640 2nd edition 04 2011 INSTRUCTIONS FOR INSTALLER USER AND SERVICE MAN IDRONIK TN 14 Instantaneousgas water heater type B ...

Page 2: ...e user 3 1 5 Safety warnings 4 1 6 Data badge 5 1 7 Guarantee condizions 5 1 8 General warnings 6 2 TECHNICAL FEATURES AND DIMENSIONS 7 2 1 Technical features 7 2 2 Dimensions 7 2 3 Main components 8 2 4 Operational data 8 2 5 General features 8 3 INSTRUCTIONS FOR THE INSTALLER 9 3 1 General warnings 9 3 2 Installation standards 10 3 3 Packaging 10 3 4 Water heater location 11 3 5 Water heater ins...

Page 3: ...e it is recommended to adjust the domestic hot water temperature as near as possible to the one you really require We recommend you to check the state of cleanliness of the heat exchanger at the end of the first year and subsequently on the basis of the lime scale found this period can be extended to two years 1 4 INFORMATIONS TO BE HANDED OVER TO THE USER 1 GENERAL INFORMATION The user has to be ...

Page 4: ...r loosening the screw pipe connections use only adequate fork spanners The improper use and or the use of inadequate equipment can cause damages for example water or gas leakages WARNING Indications for appliances operating with propane gas Ensure yourself that before installing the appliance the gas tank has been purged For a correct purging of the tank contact the liquid gas supplier or a compet...

Page 5: ...ass A Features of the D H W circuit 7 Pn Nominal Output 8 Qmax Nominal max input 9 PW Max D H W Working Pressure 10 T max Max D H W Working Temperature B Electrical Data 11 Electrical supply 12 Electrical consumption 13 Protection degree C Factory settings 14 Adjusted for gas type X D Destination countries 15 Direct and indirect destina tion countries 16 Gas category 17 Feeding pressure 18 Space f...

Page 6: ...of the ON OFF switch and or by means of the appropriate shutdown devices In the event of failure and or faulty functioning of the appliance switch off the appliance Do not attempt to make any repairs contact qualified technicians Any repairs must be carried out by Unical authorized technicians and using only original spare parts Non observance of the above requirement may jeopardize the safety of ...

Page 7: ...y II2H3P The gas water heater IDRONIK TN is complete with all the safety and control devices foreseen by the relevant Standar ds Furthermore it complies with Gas Appliances Directive 2009 142 EC ElectroMagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC 2 TEHNICAL FEATURES AND DIMENSIONS 2 2 DIMENSIONS COMPONENTS DESCRIPTION Atmospheric burner Ultraflat wet chamber heat e...

Page 8: ...put Nominal output Pn Minimum output Efficiency at nominal load Efficiency at partl load Gas type Category Nominal gas feeding pressure Burner nozzle N Off Burner nozzle Ø Smoke evacuation type kW kW kW kW mbar mm IDRONIK TN 14 2 3 MAIN COMPONENTS 1 D H W outlet1 2 2 Gas valve 3 Burner 4 Heat exchanger 5 Combustion chamber 6 Flue outlet Ø 120 7 Ignition ionisation electrode 8 Flow switch 9 Batteri...

Page 9: ... other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The connection between the boiler and chimney flue outlet can be made only after this verification has been carried out WARNING In rooms where aggressive vapours or dust are present the appliance must operate independently from ...

Page 10: ...anty card Nr 2 spare parts request coupons DO NOT DISPERS IN THE ENVIRONMENT A 450 B 825 C 210 3 2 STANDARD CODES FOR INSTALLA TION IDRONIK TN is of the gas category II2H3P The appliance must be installed in compliance to the instructions contained in this manual The installation must be carried out by a competent qualified engineer whom will assume the esponsibility of complying to all the local ...

Page 11: ...g with the gas type available This is verifiable via the indication on the packaging and on the data badge c Check that the chimney flue pipe has an adequate draught does not have any constrictions and that no other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The connection betw...

Page 12: ...fore installing the boiler it is recommended to thoroughly clean all the fuel feed pipework in order to remove any eventual residual grime which could compromise the boilers correct functioning If you smell gas a Do not turn on or off electrical switches use the telephone or any other object which can provoke sparks b Open all doors and windows in order to allow fresh air to enter and purify the r...

Page 13: ...room is not a bed room The adjacent room is not a common part of the building and is not a room with fire danger e g a fuel deposit a garage etc 3 9 FLUE GAS DISCHARGE SYSTEM Connection to the chimney A good chimney is very important for the correct functioning of the boiler it must therefore conform with the following requirements it must be made from waterproof material and be resistant at the t...

Page 14: ...for the installer 2 Ø min Slope min 3 Ø 1 5 m min 2 Ø 1 m max 1 5 m min 2 Ø Ø Slope min 3 1 m max 2 Ø min 3 Ø 3 Ø DIMENSIONS FOR THE CONNECTION OF THE SMOKE EVACUATION DUCT MINIMUM CLEARANCES 150 150 200 Ø 120 71 200 ...

Page 15: ...uch the appliance with any wet part of your body and or barefooted Do not pull the supply cables Do not expose the boiler to sunlight rain etc unless it is explicitly foreseen Do not permit children or inexpert people to use the appliance Ignition battery housing The appliance doesn t need to be connected to the electrical supply 230V It is fed by two 1 5 V batteries type D LR20 E95 AM1 ...

Page 16: ...ormations to be passed on to the user The user must be instructed on the use and operation of his water heater and in particular Hand over to the end user this manual as well as all the other literature relative to the appliance and placed in the envelope contained in the packaging The user must retain this literature for any future reference Remind the user that in order to comply to the regulati...

Page 17: ...ts prevention Make sure the flame extinguishes after the use Check the soundness of the gas connections with a soap solution If a gas leack should be detected open immediately the windows and don t switch on or use electrical appliances or connect or disconnect plugs from sockets because flames or sparks can provoque explosions If the flame is instable stop using the water heater and call an autho...

Page 18: ... the most convenient type of shower head multi func tion in order to obtain the best results in terms of temperature and quantity of water 4 3 ORDINARY MAINTENANCE Freezing prevention In case of extended periods of operation below zero it is suggested 1 Close the cold water tap 2 Rotate the draining valve E and remove it re position it when all the remaining water has been completely drained E PRE...

Page 19: ...l the service works have been done perform always the following operations Open the cold water inlet cock if previously closed Open the gas gate valve Ascertainn the gas and water soundness of the piping Refit the casing front panel 5 INSPECTION AND MAINTENANCE 6 ERROR CODES Table Anomalies prospect Instructions for inspection and main tenance In order to assure for long time the correct operation...

Page 20: ...ag info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics ...

Reviews: