background image

Unical shall not be held liable for any inaccuracies due to transcription or printing errors. 

Furthermore, it reserves the right to modify its products as deemed necessary or useful, without affecting their essential features.

 

 

46033 casteldario - mantova - Italy - tel. +39 0376 57001 - t39 0376 660556 

info@unical-ag.com - export@unical-ag.com - www.unical.eu

AG

 

S.p.A.

00335582 

- 1

st

 edition 03/15

www.unical.eu

Summary of Contents for .it AQ 15

Page 1: ... it AQ 15 INSTALLATION AND MAINTENANCE INSTRUCTIONS ...

Page 2: ...vice Centre Continuing to use the appliance in these conditions can cause fires or electrocutions In the event the supplementary air vent should not be used only for ducted models ensure fan speed is at zero disabled When installing the stove keep children away from the workplace Unexpected accidents could occur Do not block or cover the stove body in any way or obstruct the vents on top Obstructi...

Page 3: ...ith the instructions in the manuals Use which does not comply with safety directives Installation which does not comply with standards in force in the country Installation by unqualified and untrained personnel Changes and repairs not authorised by the manufacturer Use of non original spare parts Events out of the ordinary Use of pellets not approved by the manufacturer Flue The flue must comply w...

Page 4: ... parallel outlets raise the upwind chamber by one notch The flue pipe must respect the foreseen distances from combustible materials according to standards in force Chimney The chimney must meet the following requirements Have a cross section and inner shape like that of the flue Have a useful outlet cross section no less than double that of the flue The chimney coming out of the roof or in contac...

Page 5: ...al pipe can be inside or outside The smoke duct must be appropriately insulated If the smoke duct is inserted in a flue this must be authorised for solid fuels and if the diameter is larger than 150 mm it must be re established by piping and sealing the exhaust respect to the part in masonry All sections of the flue gas pipe must be able to be inspected If fixed it must have inspection openings fo...

Page 6: ...sed or a suitable protection as long as the minimum cross section is not reduced The air inflow can also be obtained from a room adjacent to the installation room as long is that flow can be obtained freely through permanent vents communicating with the outside which cannot be closed A vacuum must not be created in the room adjacent to the installation room respect to the outdoor environment by ef...

Page 7: ...suitable extension cord Safety distances for fire protection The stove must be installed while meeting the following safety conditions Minimum distance of 40 cm on sides and rear from averagely flammable materials Easily flammable materials must not be placed less than 80 cm from the front of the stove If the stove is installed onto a flammable floor a sheet of heat insulating material must be pla...

Page 8: ...e particles 3 15 mm Additives Lower Calorific Value Q Bulk density BD Nitrogen N Sulphur S Chlorine Cl Arsenic As Cadmium Cd Chromium Cr Copper Cu Lead Pb Mercury Hg Nickel Ni Zinc Zn Melting point of the ashes DT 3 M U mm mm us 1 dm 1 us us dm MJ kg us kg m3 dm dm dm dm dm dm mg kg mg kg mg kg mg kg mg kg C EN plus A1 EN plus A2 6 1 31 5 L 40 10 10 0 7 1 5 97 5 97 5 1 1 2 2 16 5 Q 19 16 3 Q 19 60...

Page 9: ...perating Connect the stove to a socket using the supplied cable Stove ignition Before lighting the stove make sure that the brazier is clear of pellets and clean from residues of previous combustion Otherwise empty and clean it Fill the tank up to 3 4 with good quality pellets compliant with that described in the standard UNI EN 14961 2 Press the ignition switch at the back of the stove the displa...

Page 10: ...tove display reads ECO TERM There are a variety of heat stove operation modes according to room thermostat setting and ambient temperature If flue gas temperature reaches 220 C during stove operation parameter which can be modified by the technician the flue gas is modulated as follows flue gas exhaust motor set at maximum speed pellet loading gearmotor at minimum speed Ignition This procedure low...

Page 11: ...dulated as follows flue gas exhaust motor set at maximum speed pellet loading gearmotor at minimum speed tangential heat exchange fan at maximum speed This procedure lowers the temperature of the flue gas When it returns below the threshold of 220 C the stove restores the speed of the three motors bringing them back to the prior setting In case of a power failure when power is restored the display...

Page 12: ...rmore it reserves the right to modify its products as deemed necessary or useful without affecting their essential features 46033 casteldario mantova Italy tel 39 0376 57001 telefax 39 0376 660556 info unical ag com export unical ag com www unical eu AG S p A 00335582 1 st edition 03 15 www unical eu ...

Reviews: