TSp Parameter
EASYr
Desciption
Min. Max.
P01
Enabled Services:
0: CH & DHW disabled
1: CH enabled
2: DHW enabled
3: CH & DHW enabled
0
3
P02
Pump: Post-circulation
0: overrun 5 min.
1: continuous
0
1
P03
Outdoor minimum
temp °C
0
30
P04
Night shift °C
0: T.A.
5÷30: Value night shift
0/5
30
P05
CH: Modulation max
0
100
P06
Sweeper mode
0: normal operation
1: 100% liv. mod. max
2: 0% liv. mod. min
1
2
P07
Displays the value correspon-
ding to the position of the
heating control panel, setpoint
of the ON-OFF request
0
1
P08
Access Code (#)
0
199
P09
bit 0 St: instantaneus, storage
tank
0
255
P10
IG - NAT: Modulation level at
start
0
100
To modify parameters is necessary password
TSp Parameter
EASYr
Desciption
Min. Max.
P11
IgL - GPL: Modulation level at
start
0
100
P12
FL - NAT: Min Fan Speed
60
40
P13
FLL - GPL: Min Fan Speed
10
40
P14
FH - NAT: Max Fan Speed
41
70
P15
FHL - GPL: Max Fan Speed
41
70
P16
HL: CH#1 Min Set point
20
45
P17
HH - CH#1 Max
Set point
50
85
P18
dL - Min ACS Set point
25
45
P19
dH - Max ACS Set point
50
65
P20
FSt - Flame stabilization time
(after ignition)
0
30
P21
Tpe - Pre ventilation time
0
5
P22
PL - Pump Min level
modulation
20
100
P23
Pr - Capacity to flow arte ratio
50
100
P24
Pdt - Pump Type
dt (°Cx2)
10
40
P25
Pt - Pump type
0 = modulating
20 ÷ 100 = pwm fix after
ignition
0/20
100
P26
Pv - Modulation Slope
1
50
P27
Hmf - Flow min CH mode
(l/h/10)
10
200
P28
BC - Boiler max capacity (kW)
10
100
P29
PMd - Max Pump delay
0
200
P30
Pld - Limit Pump delay
0
200
P31
FHCH - NAT: Fan speed Max
CH mode
41
70
P32
FHCH - GPL: Fan speed Max
CH mode
41
70