24
wARNING!
Remove the cap 2,
Insert the probe analysis
of CO2 in the cap hole 3
ATTENTION!
Function reserved for Authorised Assistance
Centres only.
1
ACTIVATION / MAXIMUM OUTPUT
Press the key + (
PLUS
) and -
(MINUS)
for at least 3
seconds: boiler at max power, symbol light .
3
MINIMUM OUTPUT
Press key -
(MINUS)
boiler at mimum power, symbol flashing.
4
DISABLING
After calibration, press the + (PLUS) and - (MINUS) at the
same time, the symbol off.
Flue gas
probe
To determine the combustion efficiency
one must make the following measurements:
- measurement of the combustion air temperature
- measurement of the flue gas temperature and content of
CO
2
taken in the relevant hole
2
.
Take the measurements with the generator in steady state
conditions (see par. 3.11.1).
3.11 - MEASUREMENT OF COMBUSTION
EFFICIENCY DURING INSTALLATION
3.11.1- ACTIVATION OF THE CALIBRATION FUNCTION
3.11.2 - POSITIONING THE PROBES
Summary of Contents for KONf 100
Page 1: ...100 115 KONf E N G L I S H INSTALLATION AND SERVICING MANUAL ...
Page 10: ...10 2 3 DIMENSIONS Front view View from above Left Side view ...
Page 38: ...38 ...
Page 39: ...39 ...