21
ENGLISH
Installation Instructions
C53x
C53
C53
NOT ALLOwED
C53
LT** (LUNGHEZZA TOTALE o LAspir LScarico)
DOUBLE Ø80
DOUBLE Ø60
FROM [m]
TO [m]
FROM [m]
TOA [m]
1 + 1
40
(max 30 S)
1 + 1
20
(max 15 S)
Separate combustion air intake and combustion
products evacuation pipes.
These pipes can discharge into areas with different
pressure.
C43x
C43
Collective chimney flue
system, consisting of two
pipes, one for combustion air intake and the other
one for combustion products evacuation, coaxial
or double.
C63x
C63
Boiler intended for connection to a combustion air
intake and combustion products evacuation system,
approved and sold separately
C83x
C83
Connection to a terminal for combustion air intake
and flue gas exhaust via a single or collective
chimney.
C93x
C93
Air / flue gas through concentric pipes in the boiler
room and single pipes in the chimney (combustion
air with counterlow in the chimney)
ATTENTION:
The flue must comply with standards
in force.