13
Instructions for the installer
3
INSTRUCTIONS FOR
THE INSTALLER
3.1 -
GENERAL WARNINGS
WARNING!
This boiler has to be destined for the use for
which it has been expressively designed for.
Any other use shall be considered improper
and therefore dangerous.
This boiler is designed to heat water at a
temperature inferior to boiling point at an
atmospheric pressure.
WARNING!
These appliances are exclusively designed
to be installed inside adequate boiler rooms.
Therefore these appliances must not be
installed and operated externally. An outdoor
installation could cause malfunctioning and
could be dangerous. For external
installations, it is recommended to use
appliances which are specifically designed
and predisposed for this purpose.
Before installing the boiler the following points
have to be carried out by a competent engineer:
a) The whole system should be thoroughly
flushed in order to remove any residual dirt or
grime which could compromise the correct
boiler operation.
b) Check that the boiler has been preset for
operating with the gas type available.
This is verifiable via the indication on the
packaging and on the data badge;
c) Check that the chimney/flue pipe has an
adequate draught,does not have any
constrictions, and that no other appliance’s flue
outlets have been fitted, unless the chimney
is serving more than one heating appliance,
according to the specific standards and
regulations in force.
The connection between the boiler and
chimney/flue outlet can be made only after this
verification has been carried out.
WARNING!
In rooms where there is the presence of
aggressive vapours or dust the appliance
must operate independently from the air
present in the boiler’s location room!
WARNING!
The appliance must be installed by a qualified
engineer, who complies to the technical-
professional requirements, who, under his own
responsibility, guarantees the compliance of
the standards according to the latest
regulations.
WARNING!
The appliance must be installed only on a
closed, vertical flat wall, made of non
combustible material.
The appliance must be positioned so that at
least the minimum operational and servicing
clearances are provided.
The boiler must be connected to a heating system which is
compatible to its performance and output.
Before boiler installation, complete all of the
following instructions:
The installation must conform to the requirements of the
authority having jurisdiction or, in the absence of such
requirements, to one of the following:
- United States - Installation must conform to the requirements
of the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
- Canada - Installation must conform to the requirements of
CAN/CSA-B149.1 - Natural Gas and Propane Installation
Code
Where required by the authority having jurisdiction, the
installation must conform to the Standard
ASME CSD-1
Controls and Safety Devices for Automatically Fired Boilers
NOTES:
- Installers must follow local regulations with respect to
installation of Carbon Monoxide (CO) Detectors. Also, follow
the maintenance recommendations in this manual.
- FOR MASSACHUSETTS INSTALLATIONS:
The boiler must
be installed by a plumber or gas fitter licensed within the
Commonwealth of Massachusetts.