3.8.1 - CONNECTION TO THE
SAFETY HEAT EXCHANGER
Solid fuel fired boilers must be installed with
the safety devices foreseen by the relevant
laws in force.
For this purpose NOVAIREX boilers are
equipped with a safety exchanger.
A
temperature relief valve
must
be installed on the safety
heat exchanger by the installation technician, with control bulb
set up inside the suitable sheath located on the rear of the
NOVAIREX
boiler.
Attention!
The input or output can be inverted as long as
the valve is installed on the cold water intake.
Provide a drain pipe with a funnel and a siphon
leading to an appropriate drainage at the heat exchanger outlet.
This drainage must be controlled on sight.
Attention!
If this precaution is not taken, triggering of
the thermal discharge valve can cause dam-
age to persons, animals and objects for which
the manufacturer cannot be held responsible.
POWER SUPPLY
DRAIN
DRAIN
DRAIN
POWER SUPPLY
POWER SUPPLY
CORRECT
INSTALLATION
INSTALLATION
WRONG