Start-up
PG-E-Series | Version 2.08
15
For electric start, turn and hold key in start switch
to “start” position until generator starts.To pro-
long the life of starter components, DO NOT hold
key in “start” position for more than 15 seconds,
and pause for at least 1 minute between starting
attempts.
Fig. 18: Electric-Starter
Schritt 5: When motor starts, move choke lever to 1/2-
CHOKE position till motor runs smoothly and
then fully into ON position. If motor flalters,
move choke back to 1/2- CHOKE position till
motor running smoothly and then fully into ON
position again.
8.3 Operation
The motor is equipped with a low oil level sensor that
shuts down the motor automatically when the oil level
drops below a specified level. If the motor shuts down by
itself and the fuel tank has enough gasoline, check motor
oil level.
Step 1: Let motor runs stable and warm up for a few mi-
nutes after starting.
Step 2: Add up the rated watts (or amps) of all loads to
be connected at one time. This total should not
be greater than the rated wattage/amperage ca-
pacity of the generator or circuit breaker rating of
the receptacle supplying the power.
Step 3: Plug in the electrical consumer(s). The consu-
mers must be switched off.
Step 4: Switch on the electrical consumer(s).
ATTENTION!
If motor fails to start after 3 pulls, or if unit shut down
during operation, make sure unit is on a level sur-
face and check for proper oil level in crankcase
(Low oil shut-off).
ATTENTION!
- Do not connect electricity consumers to the genera-
tor whose electrical characteristics are unknown or
whose characteristics differ from those of the gene-
rator (e.g. different voltages and/or frequencies).
- The generator electric circuit is protected by a cir-
cuit breaker: Any overloads and/or short circuits will
interrupt the circuit. To reactivate the circuit, re-
move the excess electricity consumers, determine
the cause of the short-circuit and/or overload and
switch on the switch again.
- Do not place any objects on the frame or directly on
the motor during commissioning of the generator:
any foreign objects could iwith proper operation.
- Do not obstruct the normal vibrations of the alterna-
tor during operation. The silent blocks are dimen-
sioned for proper operation.
ATTENTION!
If the connected consumers overheat, switch them
off and disconnect them from the generator.