Easier to Read BCD396T/UBCD396T Digital Scanner Manual
Adjusting the
Analog
AGC settings:
Turn off the Digital AGC option and turn on the Analog AGC option.
Start scanning.
Press and hold
Func
then tap the scroll knob (3 times) until AUDIO AGC settings are displayed.
Rotate the scroll control to change the setting.
Press and hold
Func
then rotate the scroll to select another setting.
Press the scroll knob to exit.
ANALOG AGC RESPONSE TIME:
Range: -4 to +6 (0 is default)
This parameter determines how frequently the AGC factor updates. Decreasing this value makes AGC respond faster, but could result in
"pumping." A higher value decreases the response time.
ANALOG AGC REFER GAIN:
Range: -5 to +5 (0 is default)
This parameter determines the reference level that AGC attempts to adjust the volume to. If digital/analog volume is not matched, adjust this
parameter.
ANALOG AGC GAIN RANGE:
Range: 0 to 15 (6 is default)
This parameter controls the total dynamic range of the AGC adjustments. A larger value allows a wider variation in volume.
Adjusting the
Digital
AGC settings:
Turn on the Digital AGC option and turn off the Analog AGC option.
Start scanning.
Press and hold
Func
then tap the scroll knob (3 times) until AUDIO AGC settings are displayed.
Rotate the scroll control to change the setting.
Press and hold
Func
then rotate the scroll to select another setting.
Press the scroll knob to exit.
DIGITAL AGC RESPONSE TIME
;
Range: -8 to +8 (0 is default)
This parameter determines how frequently the AGC factor updates. Decreasing this value makes AGC respond faster, but could result in
"pumping." A higher value decreases the response time.
DIGITAL AGC REFER GAIN
;
Range: -5 to +5 (0 is default)
This parameter determines the reference level that AGC attempts to adjust the volume to. If digital/analog volume is not matched, adjust this
parameter.
Adjust Contrast
this setting controls the display's contrast (how light or dark it appears).
Scroll to '
Adjust Contrast
' and press
E/yes
.
At '
Contrast 1-15
' scroll to the preferred contrast level
and press
E/yes
to save and exit.
PC Control
to connect your scanner to a personal computer, you must first set the scanner's baud rate (the rate at which data is transferred between the scanner and
the computer, in bits per second [bps]). Try the fastest settings first. If you have trouble transferring data between your scanner and your computer, try setting the baud
rate to a slower setting.
Scroll to '
PC Control
' and press
E/yes
.
Scroll to
Off
,
9600
,
19200
,
38400
,
57600
, or
115200
and press
E/yes
to save and exit.