background image

12

ELEMENT OF WARRANTY: Uniden warrants the original
retail owner for the duration of the Warranty, its HH955 (herein

after referred to as the Product) to be free from defects in materials

and craftsmanship with only the limitations or exclusions set

out below.
WARRANTY DURATION:  This Warranty, to the original

retail owner only, shall terminate and be of no further effect 12

months after the date of original retail sale.  This Warranty will
be deemed invalid if the Product is; (A) Damaged or not

maintained as reasonable and necessary, (B) Modified, altered

or used as part of any conversion kits, sub-assemblies, or any

configurations not sold by Uniden, (C) Improperly installed,

(D) Repaired by someone other than an authiorised Uniden

Repair Agent for a defect or malfunction covered by this
Warranty, (E) Used in conjunction with any equipment or parts

or as part of a system not manufactured by Uniden. (F) Only

available in the original country of sale.
PARTS COVERED:  This Warranty covers for one (1) year, the

HH955 Unit only.  All accessories (AC adaptor, Cables etc.) are

covered for 90 days only
STATEMENT OF REMEDY: In the event that the product
does not conform to this Warranty at any time while the Warranty

is in effect, the warrantor at its discretion will repair the defect

or replace the Product and return it to you without charge for

parts or service.
THIS WARRANTY DOES NOT COVER OR PROVIDE FOR
THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL
OR CONSEQUENTIAL DAMAGES. THIS GUARANTEE
IS IN ADDITION TO AND DOES NOT IN ANY WAY
AFFECT YOUR RIGHTS UNDER THE CONSUMER
GUARANTEE ACT.
PROCEDURE FOR OBTAINING PERFORMANCE OR
WARRANTY: In the event that the Product does not conform
to this Warranty, the Product should be shipped or delivered,
freight prepaid, with evidence of original purchase (eg. a copy
of the sales docket), to the warrantor at:

UNIDEN AUSTRALIA PTY LTD
SERVICE DIVISION
345 Princes Highway,
Rockdale, NSW 2216
Ph: (02) 9599 3355  Fax: (02) 9599 3278
Toll Free: 1300 366 895
www.uniden.com.au

UNIDEN NEW ZEALAND LIMITED
SERVICE DIVISION
150 Harris Road,
East Tamaki, Auckland
Ph: (09) 273 8383  Fx: (09) 274 4253
Toll Free: 0800 4 UNIDEN
                             (864 336)
www.uniden.co.nz

Customers in other States should ship or deliver the Product,
freight pre-paid, to their nearest Uniden Authorised Repair
Centre.
See Uniden’s Website for your nearest Warranty Agent.

WARRANTY

Summary of Contents for HH955

Page 1: ...GUIDE OPERATING 955 5WattHandheld VHFMarineRadio HH ...

Page 2: ...l give you consistent outstanding performance in many conditions and situations Uniden does not warranty this radio as watertight nor waterproof Features Dual Watch Mode One touch Channel 16 Memory Channel Scan 1 Watt or 5 Watt Transmission International Channels Back lit Display Key Pad Lock Uses AA Batteries either Alkaline or Rechargeable Nickel Cadmium not included Belt Clip Wrist Strap Techni...

Page 3: ...Transmit 8 Channel Number Controls 1 TNC Antenna Connector 2 Squelch Rotary Switch 3 On Off and Volume Control 4 Light 5 PTT Push to Talk 6 LCD Display 7 Scan 8 Dual Watch 9 MEM 10 Speaker 11 Microphone 12 Channel 16 13 Channel Up 14 1 5 Watt Transmission 15 Channel Down 16 Keypad Lock 17 Microphone Jack 18 Speaker Jack 19 AC Adaptor Input ...

Page 4: ...1 8 7 2 3 4 5 6 1 2 3 4 5 6 MARINE VHF RADIO 16 mem scan lock 1 5W SCAN DUAL MEM TX 5W 1 2 3 4 5 6 1 2 3 12 13 14 15 16 MARINE VHF RADIO 5 4 17 18 19 dual 6 7 8 9 10 11 SCAN DUAL MEM TX 5W 3 ...

Page 5: ...SCAN DUAL MEM TX 5W 4 If any of these items are missing from the box please contact your Retailer INCLUDED WITH YOUR HH955 Batteries are not included NOTE 1 Radio 1 Antenna 1 Wrist Cord 1 Belt Clip 1 AC Adaptor Optional Accessories Speaker Microphone SM040 ...

Page 6: ...ries Set the switch to either Ni Cd nickel cadmium or ALK alkaline to match the batteries being used Do not mix NiCad and Alkaline batteries CAUTION To remove the battery cover back of HH955 press on the cover grip and slide When removing batteries from the battery compartment tap the radio against your hand to dislodge the batteries and allow them to slide out Put nine batteries in the battery co...

Page 7: ...s page 5 6 As soon as the batteries are charged disconnect from the power source and radio 1 Do not over charge this will shorten the life of your rechargeable nickel cadmium batteries 2 Use only the AC Adaptor AAD955S that comes with the HH955 3 If Ni Cad batteries are being used the battery level indicator may not display full after charging Battery Level Indicator The battery level indicator wi...

Page 8: ...he 4 position SQUELCH rotary switch to eliminate background noise and select the signals you wish to receive Setting the Squelch 7 To return to channel 19 press 16 again To select a channel press or One Touch Channel 16 Example While you are monitoring channel 19 you want to check channel 16 To monitor channel 16 press 16 the channel will change from 19 to 16 Selecting a Channel Dual Watch When mo...

Page 9: ...ory press mem MEM appears in the display Select a channel to enter into memory using the up or down keys Removing Channels from Memory Select a channel that you want to remove from memory example channel 19 Once you start scanning Dual Watch comes on automatically To stop Channel scanning press scan Scanning Channels in Memory To start scanning channels in memory press scan When HH955 receives a t...

Page 10: ...ess and hold the lock key until you hear two beeps The keypad is locked If you press any key on the keypad you will hear a warning beep To unlock the keypad press and hold the lock key until you hear two beeps Key Lock Press and release the key you hear a beep The display lights for about 5 seconds If you press any key on the front keypad while the light is on the display light stays on for anothe...

Page 11: ...675 Public Corresp Duplex 62 156 125 160 725 Public Corresp Duplex 63 156 175 160 775 Public Corresp Duplex 64 156 225 160 825 Duplex 65 156 275 160 875 Duplex 66 156 325 160 925 Public Corresp Duplex 67 156 375 156 375 Safety Calling 68 156 425 156 425 Port Ops 69 156 475 156 475 Simplex 71 156 575 156 575 Fishing 72 156 625 156 625 Port Non Com l Com l 73 156 675 156 675 Non Com l 74 156 725 156...

Page 12: ... Watts Low 1 Watt Spurious Emissions 5W 40dBm Nominal Current Drain High 1 3 Amp Max 1 1 Amp Nominal Low 0 7 Amp Max 0 6 Amp Nominal Receiver Receiver Type Dual conversion super Heterodyne Phase locked Loop system for Local Oscillator Frequency Range 156 300 162 025MHz Sensitivity 0 3 V for 20dB SINAD Nominal Squelch Sensitivity Threshold 0 4 V Nominal Audio Frequency Response 3dB to 7dB 500Hz 9dB...

Page 13: ...r 90 days only STATEMENT OF REMEDY In the event that the product does not conform to this Warranty at any time while the Warranty is in effect the warrantor at its discretion will repair the defect or replace the Product and return it to you without charge for parts or service THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEQUENTIAL DAMAGES THIS GUARA...

Page 14: ...Uniden New Zealand Limited Printed in the Philippines UTZZ01884ZZ FOR PURCHASING A UNIDEN PRODUCT THANK YOU 2001 Uniden Australia Pty Limited ...

Reviews: