DROP-OUT DELAY
While scanning, the
UH-040XR
stops at a busy channel and receives a
transmission. When the received signal is over, the unit will wait for 3 seconds for
the return of the signal, otherwise, the radio resumes scanning.
KEYPAD CONFIRMANTION TONE
Assures the user that the keypad has been properly pressed by emitting a beep
tone. This tone can be switched on or off.
1. Press and hold
[SCAN]
button for 1.5 sec
“bp on”
will appear for 1.5 sec
2. Press and hold
[SCAN]
button for 1.5 secs
“bp of”
will appear for 1.5 secs and you will
hear a beep sound.
POWER SAVE
Battery Save feature extends the battery life by switching the receiver circuit
power ON and OFF. This feature automatically activates during stand by mode
(RX mode without signal). It turns OFF automatically when a signal is present,
and activates again after channel inactivity.
OS/GS
MEM
DUP
SCAN
11