background image

Product Specification / User Manual 

Load Amplifier Cassette LVCpro-

 
 

 

 
© Copyright 2010 TRsystems GmbH , Systembereich Unidor      LVCpro-SV13_E.doc    Version 1.3 /08.11.10    Page 4 of 20 

 

 

1.

 

Safety Guidelines and Regulations 

 
 

 

 

Information on Guarantee and Liability

 

 

 

 

Our 

“general  terms  and  conditions  on  sale  and  delivery”  generally  apply

These are available to the operator from the completion of the contract at the latest . 
Guarantee  and  liability  claims  for  personal  and  material  damages  are  excluded  if 
caused by one or more of the following: 
 

 

Improper use of the device. 

 

Improper installation, commissioning, operation and maintenance of the device. 

 

Operation of the device or machines thereof with faulty safety equipment or with 
improper or inoperable safety and protection equipment. 

 

Failure to observe the regulations of the user manual. 

 

Unauthorised structural changes on the device or machines thereof. 

 

Unauthorised modifications to the settings of the initial operation. 

 

Insufficient control of parts subject to wear. 

 

Improper repairs of unqualified workers. 

 

Disaster situations caused by third parties or force majeure.

 

 

 

 

 

 

 

Disclaimer / Right of Amendment 

 

 

 

This user manual is kept up to date. As the 

TR

systems

 

GmbH

UNIDOR 

products 

are subject to continual development technical modifications might lead to temporary 
deviations  between  the  device  design  and  the  user  manual.  Please  note  that 

TR

systems

 

GmbH 

is not liable for damages caused as a result of these deviations. 

 

 

 

 

 

 

Due Diligence of the Operator

 

 

 

 

 
 
 
 

The 

LVCpro-S

  was  designed  and  constructed  followinga  risk  analysis  and  upon 

careful  selection  of  the  relevant  standards  to  be  complied  with,  as  well  as  other 
technical  specifications.  It  is  state-of-the-art  and  ensures  the  maximum  possible 
safety during operation. 
However,  the  machine  safety  can  only  be  implemented  if  all  necessary  measures 
have  been  taken.  The  planning  of  these  measures  as  well  as  the  control  of  their 
implementation is part of the due diligence of the operator. 
 

The operator must ensure that ... 
 

 

the machine is used in accordance with its intended purpose. 

 

necessary  personal  protective  equipment  for  the  operation,  maintenance  and 
repair is available and used. 

 

the machine is only operated, serviced and repaired by qualified personnel. 

Summary of Contents for LVCpro-S

Page 1: ...H Freiburgerstra e 3 75179 Pforzheim Germany Tel 07231 3152 0 Fax 07231 3152 99 email unidor trsystems de Web http www trsystems de This user manual is kept up to date As the TRsystems GmbH UNIDOR pro...

Page 2: ...of LVCpro S Advantages Functionality Easy installation and wiring 24VDC supply voltage 2 measuring channels Peak value memory and current value available at the same time Switchable filter for suppre...

Page 3: ...14 Safety Guidelines and Regulations Technical Specification Block Diagram Terminal Assignment Connector Coding Connection of the Piezo Sensors Setting of the Code Switches Amplification Factors Setti...

Page 4: ...airs of unqualified workers Disaster situations caused by third parties or force majeure Disclaimer Right of Amendment This user manual is kept up to date As the TRsystems GmbH UNIDOR products are sub...

Page 5: ...the intended purpose The company TRsystems UNIDOR is not liable for damages caused following other usage Intended use also means only using the device in immaculate condition removing interferences w...

Page 6: ...responding situations For 24VDC power supplies a safe electric isolation of the low voltage is important Only use power supplies designed acc to IEC 364 4 41 respectively HD 384 04 41 VDE 0100 part 41...

Page 7: ...trol and must be separated from supply lines stressed with disturbances shielded Ensure a continuous wiring of the shield as well as an extensive contact between the shield and the electric terminals...

Page 8: ...sistance Output resistance 1015 Ohm 50 Ohm Measuring Window Input Cams Input voltage Input current Function 18 32VDC ca 10mA at 24VDC active high 1 Output low 0 deletes analogous signal Output Data Ou...

Page 9: ...s 1 Meas Channel 1 Cams 2 Meas Channel 2 0VDC PiezoSensor 2 IN2 GND CASE Input Signal Sensor 2 Analogous Mass Shield PiezoSensor 1 IN1 GND CASE Input Signal Sensor 1 Analogous Mass Shield bottom conne...

Page 10: ...Load Amplifier Cassette LVCpro S Copyright 2010 TRsystems GmbH Systembereich Unidor LVCpro SV13_E doc Version 1 3 08 11 10 Page 10 of 20 5 Connector Coding 1x 1x 2x 4x Power CAM 1 2 PiezoSensor 1 Piez...

Page 11: ...nal assignment for tensile load Sensors Connector LVCpro S Core Colour PIN Press Force Sensor 1 Piezosensor 1 red black Shield IN1 GND CASE Press Force Sensor 2 Piezosensor 2 red black Shield IN2 GND...

Page 12: ...nts will be implemented separately for each channel Channel Sensor Code Switch Function Channel 1 2 SW1 Filter adjustment Channel 1 SW201 Code switch for capacitive rough amplification Piezo Sensor 1...

Page 13: ...itive amplification Code switch SW201 SW401 Capacity nF Amplification Adjustment Code switch SW202 SW402 Amplification factor times 0 71 8 0 11 12 1 65 0 1 11 08 2 61 8 2 11 03 3 55 0 3 10 96 4 49 8 4...

Page 14: ...lifier 50 SV3 SV4 P102 P302 8 Settings for DIP Switches or Filters SW1 Channel 1 Piezo Sensor 1 DIP Switch Function ON OFF Default Factory setting with filter F limit 1KHz 1 2 Turn on either only swit...

Page 15: ...ither of them F limit 1KHz 33nF Default 7 8 OFF 7 F limit 100Hz 220nF II 33nF 7 ON 8 OFF 8 F limit 355Hz 47nF II 33nF 8 ON 7 OFF 9 Commissioning of the LVCpro S Wiring of the piezo sensors Wire the me...

Page 16: ...ill enable an assessment in case of an overload If replacing the load amplifier cassette LVCpro S it is important to maintain the same adjustment of the code switches otherwise there is the risk of ov...

Page 17: ...anual Load Amplifier Cassette LVCpro S Copyright 2010 TRsystems GmbH Systembereich Unidor LVCpro SV13_E doc Version 1 3 08 11 10 Page 17 of 20 additional cable length available on request 11 Mechanica...

Page 18: ...pro SV13_E doc Version 1 3 08 11 10 Page 18 of 20 12 Opening the LVCpro S Enclosure 1 Use a screwdriver to push the splint in the opening tab down located underneath the connector plugs of Power Piezz...

Page 19: ...the adjustment and or calibration of the press force are accessible 14 General Information EC Declaration of Conformity Manufacturer TRsystems GmbH System Division Unidor Factory Unidor Freiburger Str...

Page 20: ...e LVCpro S Copyright 2010 TRsystems GmbH Systembereich Unidor LVCpro SV13_E doc Version 1 3 08 11 10 Page 20 of 20 EN 55022 Radio Radiation VDE 0100 VDE 0113 EN 60204 Issued by TRsystems GmbH System D...

Reviews: