16
888-994-7636
Control Settings con’t
DIXELL CONTROL SETTING INSTRUCTIONS
HOW TO CHANGE A PARAMETER VALUE
To change the parameter’s values operate as follows:
1. -
Enter the Programming mode by pressing the Set and Down Arrow for 3
seconds (the defrost and water drops symbol will start blinking)
2. -
Select the required parameter.
3. -
Press the “SET” key to display its value. (Now only the defrost symbol is
blinking).
4. -
Use up or down arrow to change its value.
5. -
Press “SET” to store the new value and move to the following parameter.
To Exit: Press SET + up arrow or wait 15 seconds without pressing a key.
THE HIDDEN MENU
The hidden menu includes all the parameter of the instrument.
HOW TO ENTER THE HIDDEN MENU
1. -
Enter the Programming mode by pressing the set + down arrow key for 3
seconds (the defrost and water drops symbol will start blinking)
2. -
When a parameter is displayed; keep pressed the Set + down arrows for
more than 7 seconds. The Pr2 label will be displayed immediately
followed from the HY parameter.
NOW YOU ARE IN THE HIDDEN
MENU.
3. -
Select the required parameter.
4. -
Press the
“SET”
key to display its value (Now only the defrost symbol LED
is blinking).
5. -
Use up or down arrow to change its value.
6. -
Press
“SET”
to store the new value and move to the following parameter.
HOW TO LOCK THE KEYBOARD
1. -
Keep pressed for more than 3 seconds the up and down arrow keys.
2. -
The
“POF”
message will be displayed and the keyboard will be locked. At
this point it will be possible only to see the set point or the
MAX
or
Min
temperature stored.
3. -
If a key is pressed more than 3 seconds the
“POF”
message will be
displayed.
TO UNLOCK THE KEYBOARD
1. -
Keep pressed together for more than 3 seconds the up and down arrow
keys till the
“POn”
message will be displayed.
Summary of Contents for Randell 2127AC